X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 2
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 3
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 4
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 5
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 6
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 7
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 8
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 9
-30%
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 2
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 3
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 4
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 5
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 6
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 7
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 8
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K view 9

X-Pro 35,000 BTU 4 Zone Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K + 12K

sold in last days
Regular price $6,471.00 Sale price $4,529.00
Save $1,942.00
In Stock

Fast delivery

Arrives quickly and safely

Buyer protection

Covered end to end

Secure packaging

Damage-free guarantee

Ships from

ValuHub Fulfillment

X-Pro 35000 BTU 4 Zone 22.5 SEER2 Mini Split AC with Heat Pump-9K + 9K + 9K + 12K

X-Pro 35,000 BTU 4 Zone Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K + 12K

$4,529.00
Description

X-Pro 35,000 BTU 4 Zone Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K + 12K

Three 9,000 BTU indoor units and one 12,000 BTU unit share one 35,000 BTU condenser, so the busiest room gets the extra capacity without oversizing the other three. Published ratings are 22.5 SEER2 on cooling and 10 HSPF2 on heating, running R454B refrigerant, with heating listed down to -25°C (-13°F).

22.5 SEER2 coolingHeating rated to -25°CR454B refrigerantWifi, remote and voice control

One room in the house always runs a couple of degrees out

What usually goes wrong

Three rooms behave and the fourth never quite matches. It might face west, sit over the garage, or have one more window than the others. Turning the whole system harder is an expensive way to fix one room.

How this configuration answers it

The odd room gets a 12,000 BTU head instead of the 9,000 BTU used on the other three, with its own controller to hold it there. Only the zones that are switched on draw from the 35,000 BTU outdoor unit.

Four heads on one condenser is the practical middle ground for a Canadian house with uneven rooms: real heating as well as cooling, and no ductwork to build. Everything indoors connects back to the same 35,000 BTU outdoor unit through its own insulated copper line set.

Four slim white indoor units stacked above a white outdoor unit, with a coiled copper line set, a communication wire, four remotes and a phone showing the app set to 70

Everything that arrives on the pallet

The photo is the full delivery: a 35,000 BTU outdoor unit, four indoor units rated 9,000, 9,000, 9,000 and 12,000 BTU, four remotes, the coiled copper line sets and the communication wire that ties each head back to the condenser. The system runs on R454B, a lower global warming potential refrigerant than the R410A on older equipment.

Reading the yellow label

The yellow label and the badges beside it are the whole efficiency story: 22.5 SEER2 for cooling, 10 HSPF2 for heating, R454B refrigerant, and ENERGY STAR. The small graph shows the inverter line holding almost flat while the non inverter line swings above and below the set point all day.

EnergyGuide label and an ENERGY STAR mark beside a wall unit and a white outdoor unit, with R454B refrigerant, 22.5 SEER2 and 10 HSPF2 called out and an inverter versus non inverter temperature graph below
White outdoor unit standing on a split background of desert sand and deep snow, with the chassis heater glowing at its base, captioned cool even at 55 degrees Celsius and heat even at minus 25 degrees Celsius

The number that matters in February

The split background is the operating window: cooling up to 55°C (131°F) and heating down to -25°C (-13°F), with chassis electrical heating keeping the base pan clear. Natural Resources Canada points out that output falls as the outdoor air gets colder, so a backup heat source is still worth having.

Bedroom zones after lights out

The curve in the photo runs from conversation level down to 30 dB at the lowest fan speed. Screen off kills the display, sleep mode drifts the set point through the night, and the 24H timer can shut the zone down at a set hour. That combination is what makes a head over a bed tolerable.

Dark bedroom with a wall unit above the bed and a sound curve falling from 50 dB through 40 dB to as low as 30 dB, with sleep mode, 24H timer and screen off labels underneath

What you get

Four zones, one compressor

One 35,000 BTU outdoor unit runs all four indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing to leave alone.

Matching each unit to its room

A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.

Inverter compressor

The compressor varies its speed instead of cycling on and off. Published ratings are 22.5 SEER2 for cooling and 10 HSPF2 for heating on R454B refrigerant.

Built for a Canadian winter

A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F).

Line sets and wiring supplied

Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire, plus a drain hose. That is the material most quotes list separately, four times over on a system this size.

Electrical supply

The outdoor unit runs on 208-230V 60Hz. This is not a standard 15 amp household outlet. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.

Controls

Wifi app, a remote with a digital display for each zone, and voice control through Alexa or Google Home. A 24 hour timer and a child lock are built in.

Filters you can rinse

The indoor filters pull out, rinse under a tap and go back in. Four heads means four sets, and clean filters are the cheapest way to keep airflow and running cost where they should be.

Specifications

X-Pro, 35,000 BTU outdoor unit with 9,000, 9,000, 9,000 and 12,000 BTU indoor units
Zones 4 (one outdoor unit, four indoor units)
Outdoor unit capacity 35,000 BTU
Indoor unit capacities 9,000, 9,000, 9,000 and 12,000 BTU
System type Ductless heat pump, cooling and heating
SEER2 (cooling) 22.5
HSPF2 (heating) 10
Refrigerant R454B
Power supply 208-230V 60Hz
Heating range Down to -25°C (-13°F)
Cooling range Up to 55°C (131°F)
Operating modes 7: auto, cool, heat, dry, fan, ECO, sleep
Fan speeds 8: auto, mute, low, low-mid, mid, mid-high, high, turbo
Indoor sound level From 30 dB
Certification ENERGY STAR, ETL and AHRI
Line set supplied 16 ft per zone, insulated copper (gas and liquid)
Communication wire 19 ft per zone
Drain hose One per zone, length not published
Outdoor unit size 42.28 x 18.43 x 33.58 in (L x W x H)
Indoor unit size, 9,000 BTU 32.28 x 7.68 x 12.05 in (L x W x H)
Indoor unit size, 12,000 BTU 36.22 x 7.68 x 12.05 in (L x W x H)
Colour White
Manufacturer SKU 58691825_X-Pro-36K-19

Capacity by zone

Rated capacity of each of the four zones in BTU Zone 19,000 BTUZone 29,000 BTUZone 39,000 BTUZone 412,000 BTUOutdoor unit rated 35,000 BTU
Rated capacity of each indoor unit in this configuration, drawn to the same scale, with the outdoor unit total underneath. At the common rule of thumb of 20 to 25 BTU per square foot, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Use CSA F280-12 for a real load calculation.

How it compares

Three ways people usually fix four uneven rooms in a Canadian home. This is how they differ in practice, not in price.

  This 4 zone system A window or portable unit per room Adding central ducted air
Separate temperature per room Yes, four independent set points Yes, but each room needs its own machine Usually one thermostat for the whole zone
Heats as well as cools Yes, rated to -25°C (-13°F) Many are cooling only Depends on the furnace or air handler fitted
Ductwork None, one cored hole per zone None Full duct network to every room
Machines outside One outdoor unit One in every window One condenser plus the indoor plant
Windows stay clear Yes No Yes
Who installs it Licensed HVAC and electrical trades You do, out of the carton Licensed trades, often several days on site

Shipping

Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.

Returns

Return within 14 days of purchase, unused, in original condition and packaging.

Warranty

Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.

Who is this perfect for?

Three bedrooms and a slightly larger main room

The 12,000 BTU zone suits roughly 480 to 600 sq ft and the three 9,000 BTU zones roughly 360 to 450 sq ft each. A common shape for a bungalow or a semi.

Homes with no ducts to extend

Older houses, additions, attic conversions and finished basements rarely have duct where it is needed. Four zones from one outdoor unit avoids opening up ceilings.

Households that want heat as well as cooling

This is a heat pump, not a cooling only air conditioner. It carries a 10 HSPF2 heating rating and a chassis electrical heater on the outdoor unit for cold weather.

Dimension chart listing indoor unit sizes from 9,000 to 24,000 BTU and outdoor unit sizes from 18,000 to 35,000 BTU, with ETL and AHRI certified marks in the corner

What we stand behind

  • Ships from a Canadian warehouse, with free shipping on orders over $150
  • 14 day returns on unused items in original condition and packaging
  • Covered by the manufacturer's own warranty for material and manufacturing defects
  • Line sets, communication wire and a controller for every one of the four zones are in the box

Frequently asked questions

How much space will each indoor unit cover?

Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Poor insulation, large west facing windows or a 9 ft ceiling all push the figure up.

The four indoor units add up to 39,000 BTU but the outdoor unit is 35,000 BTU. Is that a mistake?

No. On any multi zone system the indoor ratings are not meant to be added together, and multi zone sizing guides say so plainly. The 35,000 BTU figure is what the outdoor unit can deliver at one time, shared among whichever zones are calling for it. Four rooms rarely peak at the same moment, which is why this combination is offered.

How cold can it get outside before it stops heating?

The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most newer units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.

Can I install this myself in Canada, and does it run on a normal outlet?

No on both counts. The outdoor unit runs on 208-230V 60Hz, so it needs its own branch circuit and an electrician, not a wall socket. Refrigerant work is also regulated: Ontario, for example, states that only a certified technician may remove, discharge, handle and dispose of refrigerants including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of that. Other provinces have their own halocarbon rules, and the federal Code of Practice says the same thing in plainer terms.

Recently viewed products