UltrEco 24,000 BTU 3 Zone Mini Split Heat Pump, 23 SEER2, Wifi, 7K + 7K + 9K
Fast delivery
Arrives quickly and safely
Buyer protection
Covered end to end
Secure packaging
Damage-free guarantee
Ships from
ValuHub Fulfillment
UltrEco 24,000 BTU 3 Zone Mini Split Heat Pump, 23 SEER2, Wifi, 7K + 7K + 9K
Description
UltrEco 24,000 BTU 3 Zone Mini Split Heat Pump, 23 SEER2, Wifi, 7K + 7K + 9K
The three indoor units supplied measure 7,000, 7,000 and 9,000 BTU, and only the ones you switch on draw from the 24,000 BTU outdoor unit. It runs on R32 refrigerant, is rated 23 SEER2 and 10 HSPF2, and the manufacturer lists heating down to -25°C (-13°F).
The one room that never matches the rest of the house
What usually goes wrong
A bedroom over the garage bakes in July while the basement stays cold. A window unit fixes one room and takes the window with it. Running the whole house harder to fix one room costs money and still misses the far corner.
How this configuration answers it
Three indoor units of 7,000, 7,000 and 9,000 BTU each get their own controller and their own temperature. Run the 9,000 BTU unit hard in the problem room and leave the other two off. Only the zones you switch on draw from the 24,000 BTU outdoor unit.
Three zones off one condenser sits between a window unit in every room and a full ducted system. You get separate control in each space without opening ceilings to run ducts everywhere.

Everything that comes on the pallet
Laid out here is the whole kit: the 24,000 BTU outdoor unit, three white indoor units rated 7,000, 7,000 and 9,000 BTU, a remote for each one, the insulated copper line sets and the tape, putty and wiring that join them up. Each indoor unit answers to its own remote, so the 9,000 BTU unit can run hard while the other two idle.
Bedroom zones and the screen off setting
Three things make a bedroom zone liveable: a sleep curve that drifts the set point overnight, a display that switches off completely, and a timer that can stop the zone at a set hour. The 7,000 BTU unit is rated 30 dB indoors.


Reading the yellow label
The EnergyGuide panel in this photo is the honest summary: 23 SEER2 on cooling, 10 HSPF2 on heating, with R32 refrigerant in the system. The graph beside it shows why an inverter holds temperature better than a fixed-speed compressor that only knows on and off. It carries ENERGY STAR, ETL and AHRI certification.
What the buttons on the remote do
Dry mode pulls humidity without overcooling, fan mode moves air with the compressor off, and sleep mode drifts the set point overnight. There are 6 modes (auto, cool, heat, dry, fan, sleep) in total and 5 fan speeds, plus a 24 hour timer and auto swing. On smaller zones like these the low and auto speeds cover most of the year.

What you get
Three zones, one compressor
One 24,000 BTU outdoor unit runs all three indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing.
Matching each unit to its room
A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). Here, a 7,000 BTU unit suits roughly 280 to 350 sq ft and a 9,000 BTU unit suits roughly 360 to 450 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.
Inverter compressor
The compressor varies its speed instead of cycling on and off. Published ratings are 23 SEER2 for cooling and 10 HSPF2 for heating.
Built for a Canadian winter
A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 52°C (125°F).
Line sets and wiring supplied
Each zone gets a 16 ft insulated copper line set and 13 ft of communication wire, plus a 6.5 ft drain hose. That is the material most quotes list separately.
Electrical supply
The outdoor unit runs on 208-230V~60Hz, single phase. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.
Controls
Wifi app plus a remote with a digital display for each zone, and a 24 hour timer.
Filters you can rinse
The indoor filters pull out, rinse under a tap and go back in. Clean filters are the cheapest way to keep airflow and running cost where they should be.
Specifications
| Zones | 3 (one outdoor unit, three indoor units) |
|---|---|
| Outdoor unit capacity | 24,000 BTU |
| Indoor unit capacities | 7,000, 7,000 and 9,000 BTU |
| System type | Ductless heat pump, cooling and heating |
| SEER2 (cooling) | 23 |
| HSPF2 (heating) | 10 |
| Refrigerant | R32 |
| Power supply | 208-230V~60Hz, single phase |
| Heating range | Down to -25°C (-13°F) |
| Cooling range | Up to 52°C (125°F) |
| Operating modes | 6: auto, cool, heat, dry, fan, sleep |
| Fan speeds | 5: auto, low, mid, high, strong |
| Indoor sound level | From 30 dB |
| Certification | ENERGY STAR, ETL and AHRI |
| Line set supplied | 16 ft per zone, insulated copper (gas and liquid) |
| Communication wire | 13 ft per zone |
| Drain hose | 6.5 ft per zone |
| Outdoor unit size | 38.6 x 15.3 x 27.6 in (L x W x H) |
| Indoor unit size, 7,000 BTU | 31 x 7.8 x 11.5 in (L x W x H) |
| Indoor unit size, 9,000 BTU | 31 x 7.8 x 11.5 in (L x W x H) |
| Colour | White |
| Manufacturer SKU | 41635424_UltrEco-24K-09 |
Capacity by zone
How it compares
Three ways people usually fix uneven rooms in a Canadian home. This is how they differ in practice, not in price.
| This 3 zone system | A window or portable unit per room | Adding central ducted air | |
|---|---|---|---|
| Separate temperature per room | Yes, three independent set points | Yes, but each room needs its own machine | Usually one thermostat for the whole zone |
| Heats as well as cools | Yes, rated to -25°C (-13°F) | Many are cooling only | Depends on the furnace or air handler fitted |
| Ductwork | None, one cored hole per zone | None | Full duct network to every room |
| Indoor equipment on show | Three slim units mounted high on a wall | A machine in every window | Vents and returns |
| Windows stay clear | Yes | No | Yes |
| Who installs it | Licensed HVAC and electrical trades | You do, out of the carton | Licensed trades, often several days on site |
Shipping
Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.
Returns
Return within 14 days of purchase, unused, in original condition and packaging.
Warranty
Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.
Who is this perfect for?
A main room and two smaller ones
The 9,000 BTU unit takes the busiest space, roughly 360 to 450 sq ft, while the 7,000 BTU units handle quieter rooms. Capacity goes where the heat load actually is.
Homes with no ducts to extend
Older houses, additions, attic conversions and finished basements rarely have ducts where they are needed. Three zones from one outdoor unit avoids opening up ceilings.
People who want heat as well as cooling
This is a heat pump, not a cooling-only air conditioner. It carries an HSPF2 heating rating of 10 and a chassis heater for winter operation.

What we stand behind
- Ships from a Canadian warehouse, with free shipping on orders over $150
- 14 day returns on unused items in original condition and packaging
- Covered by the manufacturer's own warranty for material and manufacturing defects
- Line sets, communication wire and a controller for every zone are in the box
Frequently asked questions
How much space will each indoor unit cover?
Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. Here, a 7,000 BTU unit suits roughly 280 to 350 sq ft and a 9,000 BTU unit suits roughly 360 to 450 sq ft. Poor insulation, big west-facing windows or a 9 ft ceiling all push that figure up.
The three indoor units add up to 23,000 BTU and the outdoor unit is rated 24,000 BTU. Why the gap?
Multi-zone outdoor units come in fixed sizes and the indoor combinations are built around them, so the totals rarely land exactly. The spare capacity is not wasted: the inverter compressor simply runs at a lower speed, which is where a modulating system gets its efficiency. Either way, do not add the indoor ratings together to judge the system. The 24,000 BTU figure is what can be delivered at one time, shared among the zones that are calling.
How cold can it get outside before it stops heating?
The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.
Can I install this myself in Canada?
Plan on a licensed installer. In Ontario, for example, the province states that by law only a certified technician may remove, discharge, handle and dispose of refrigerants, including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of the refrigerant certificate. Other provinces have their own halocarbon rules. The federal Code of Practice says the same thing in plainer terms: the technician doing work that could release refrigerant must hold the proper environmental certification. The 208-230V~60Hz, single phase power supply also means an electrician and a dedicated circuit.




















