UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 2
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 3
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 4
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 5
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 6
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 7
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 8
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 9
-60%
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 2
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 3
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 4
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 5
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 6
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 7
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 8
UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K view 9

UltrEco Series 18,000 BTU 2 Zone Mini Split Heat Pump with WiFi, 22 SEER2, 9K + 9K

sold in last days
Regular price $3,918.00 Sale price $1,549.00
Save $2,369.00
Available to Backorder

Fast delivery

Arrives quickly and safely

Buyer protection

Covered end to end

Secure packaging

Damage-free guarantee

Ships from

ValuHub Fulfillment

UltrEco Series 18000 BTU 2 Zone 22 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K

UltrEco Series 18,000 BTU 2 Zone Mini Split Heat Pump with WiFi, 22 SEER2, 9K + 9K

$1,549.00
Description

UltrEco Series 18,000 BTU 2 Zone Mini Split Heat Pump with WiFi, 22 SEER2, 9K + 9K

Cooling through the summer and heat pump heating through the winter, from one 18,000 BTU outdoor unit split across two 9,000 BTU heads, each a 0.75 ton. Rated 10 HSPF2 for heating and published down to -25 C (-13 F) outdoors.

18,000 BTU across 2 zonesTwo 9,000 BTU unitsHeats to -25 C (-13 F)

Two rooms, two thermostats, one outdoor unit

What usually goes wrong

Two rooms in the house never match the thermostat. The upstairs bedroom runs hot every July and the back room or basement office runs cold every February. Turning up the furnace or the central air conditions the whole house to fix two rooms.

How this configuration answers it

Two matched 9,000 BTU units run off one outdoor unit, each with its own set temperature and its own fan speed. The pair is balanced, so neither room gets the short end when both call at once. No ducts get cut and no window gets blocked.

One compressor, two indoor units, one small wall penetration per zone. That is the whole idea, and it is why ductless equipment ends up in houses where cutting new ductwork would mean opening ceilings and rebuilding soffits.

The outdoor condenser, two slim white wall heads, a coiled copper line set, drain hose, two remotes and a phone showing the control app, laid out together

What is in the boxes

The carton holds one outdoor condenser, two wall mounted heads, and two 16 ft copper line sets (3/8 in gas, 1/4 in liquid), two 13 ft communication wires, two 6.5 ft drain hoses, two remotes, two mounting plates, wall sleeves, caps, tape, putty and screw kits. The outdoor unit measures 34.7" x 13.9" x 21.9" and weighs 75 lb. The indoor units are a matched pair of 9,000 BTU wall mounted heads, 17.5 lb each, measuring 31" x 7.8" x 11.5".

Matching capacity to rooms

Both indoor units are 9,000 BTU: a 0.75 ton each, 35.5 pints a day of moisture removal, and 30 dB on the quietest fan speed. Those are the manufacturer's nameplate figures. Natural Resources Canada asks for a recognised load calculation, CSA F280, before a heat pump is chosen, because floor area alone does not tell you what a room actually loses on a cold night.

A bright living room with a slim wall head mounted above the sofa while two children play and a woman checks the app on her phone
The outdoor unit sitting on a snow covered ledge with the base heater glowing orange, desert heat on the left, and the cooling and heating temperature limits called out

What happens once it drops below freezing

Heating output on any air source heat pump falls as the outdoor air gets colder. The manufacturer rates this outdoor unit to keep heating down to -25 C (-13 F) and to keep cooling up to 52 C (125 F), and fits a chassis heater that keeps the base pan from icing up. What that figure does not tell you is your balance point, the outdoor temperature below which the heat pump can no longer carry the load on its own. Natural Resources Canada describes that point and the backup heat that takes over below it; your installer works it out for your house.

Filters, noise and day to day control

Filters slide out of the front panel and rinse under the tap, which is the maintenance most owners actually do. Both heads are rated at 30 dB on their quietest setting. Controls run through the wifi app or the backlit remote, with 6 modes (auto, cool, heat, dry, fan and sleep) and 5 fan speeds, a 24 hour timer and a set range of 60 F to 90 F.

The wall head with its front panel lifted to show the filter, and a hand rinsing a filter under running water

What you get

Two zones, two set temperatures

Each indoor unit has its own controller and its own target temperature, so one room can sit at 20 C while the other sits at 23 C, from one outdoor unit and one circuit. Both zones share that one compressor: output is divided when they call at once, and the manufacturer does not publish simultaneous heating and cooling for this system, so do not plan on it.

Inverter compressor

Rated 22 SEER2 for cooling and 10 HSPF2 for heating. The compressor ramps its speed up and down to hold a temperature instead of switching hard on and off.

R32 refrigerant

R32 carries a global warming potential of 675, well under a third of the R410A it replaces, and is rated A2L, which means low toxicity and mild flammability.

Chassis heater on the outdoor unit

Rated to keep heating down to -25 C (-13 F) and cooling up to 52 C (125 F). The heated base pan is there to stop meltwater freezing under the coil during a defrost cycle.

Wifi app and a backlit remote

Set and monitor each zone from the app or from the remote that ships with each head. A 24 hour timer handles schedules, and the set range runs 60 F to 90 F.

Line sets in the box

Two 16 ft copper line sets, communication wire, drain hoses and mounting hardware ship with the system. The manufacturer does not publish a maximum line length for this model, so have your installer confirm the runs before the holes are cut.

208-230V power

This is not a plug in appliance. It needs a dedicated 208-230V, 60 Hz, single phase circuit and a disconnect at the outdoor unit, wired by an electrician. The indoor units are fed from the outdoor unit, not from separate outlets.

Certified to Energy Star, AHRI and ETL

The manufacturer lists this series as Energy Star, AHRI and ETL certified. Certification marks also appear on the specification photo in the gallery.

Specifications

UltrEco Series 18,000 BTU two zone system, 9K + 9K indoor units
Zones 2 (one outdoor unit, two independently controlled indoor units)
Outdoor unit capacity 18,000 BTU
Indoor units two 9,000 BTU wall mounted heads
SEER2 (cooling) 22
HSPF2 (heating) 10
Refrigerant R32
Power supply 208-230V, 60 Hz, single phase
Operating range heating down to -25 C (-13 F), cooling up to 52 C (125 F)
Temperature setting range 60 F to 90 F
Outdoor unit dimensions 34.7" x 13.9" x 21.9" (L x W x H)
Outdoor unit weight 75 lb
Indoor unit dimensions 31" x 7.8" x 11.5" (L x W x H), 17.5 lb each
Heat pump rating 0.75 ton per unit
Dehumidification 35.5 pints a day per unit
Indoor sound level 30 dB
Line set diameters air 3/8", liquid 1/4"
Line sets included two 16 ft copper line sets
Colour White
Certification Energy Star, AHRI and ETL
Manufacturer warranty published 7 years on the compressor and 5 years on parts
Manufacturer SKU UltrEco-18K-05

The numbers on this configuration

Key ratings for this two zone system Rated figures for this configuration18,000Outdoorunit BTU9,000Zone 1BTU9,000Zone 2BTU22SEER2cooling10HSPF2heating
SEER2 is the seasonal cooling efficiency rating and HSPF2 the seasonal heating rating: higher is better on both. The zone figures are nameplate capacities for the two indoor units. Natural Resources Canada asks for a recognised load calculation such as CSA F280 before any heat pump is chosen for a home.

How it compares

Three other ways people fix a room that is too hot or too cold, set beside this one. The comparisons are general category differences, not tests of named products.

  This 2 zone system Window or portable units Central air or furnace alone Adding ducts to the room
Rooms controlled separately Two, each with its own set temperature Each unit is separate but only cools One thermostat sets the whole house Depends on dampers and zoning
Heating as well as cooling Yes, heat pump rated to -25 C (-13 F) Cooling only on most units Yes, from the existing furnace Yes, from the existing furnace
Window space Nothing in the window Blocks a window through the season Nothing in the window Nothing in the window
Construction work Wall penetrations for the line sets None None Framing, drywall and finishing
Who can install it Licensed HVAC trade, refrigerant handling is regulated Homeowner Licensed trade for the equipment Licensed trade
Seasonal storage Stays in place year round Hauled out and stored every autumn Stays in place Stays in place

Shipping

Ships from a Canadian warehouse. Free shipping on orders over $150; some remote areas, PO boxes and surcharge regions may cost extra.

Returns

Return within 14 days of purchase, unused, in original condition and packaging.

Warranty

Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.

Who is this perfect for?

Houses with no ductwork

Older homes on hot water or electric baseboard get cooling and heat pump heating without a duct being cut, since the refrigerant lines need only a small wall penetration.

Two rooms of similar size

Both indoor units are 9,000 BTU, so the pair suits two comparable spaces: two bedrooms, or a main floor split into two areas.

Owners planning a proper install

Refrigerant work is regulated in every province, and the manufacturer requires a professional technician. This suits buyers who already have an HVAC contractor and an electrician lined up.

Flat lay of everything in the carton: the outdoor unit, two indoor heads, remotes, wall sleeve, drain hose, coiled copper pipe, mounting plate, communication wire, tape, putty, wall caps and screw kit

What we stand behind

  • One outdoor unit, two indoor units and two 16 ft line sets in the box
  • Ships from a Canadian warehouse, free shipping over $150
  • 14 day returns on unused product in original packaging
  • Covered by the manufacturer's warranty for material and manufacturing defects

Frequently asked questions

Can a homeowner install this, or is a licensed installer required?

The manufacturer states that professional installation is required for this system. In Canada, handling refrigerant is regulated province by province, and provinces require trained service providers for installing, servicing and decommissioning equipment that contains halocarbons. Ontario, as one example, restricts removing, discharging and disposing of refrigerants to certified technicians and requires a separate trade Certificate of Qualification to actually work on the equipment. Budget for an HVAC contractor and an electrician.

What electrical supply does it need?

A dedicated 208-230V, 60 Hz, single phase circuit, not a wall outlet. On a multi zone system the indoor units are powered from the outdoor unit rather than from their own plugs, and code calls for a disconnect at the outdoor unit. An electrician sizes the breaker and wire from the unit's own nameplate.

What size room does each indoor unit suit?

The manufacturer rates the 9,000 BTU unit at 0.75 ton and the 9,000 BTU unit at 0.75 ton, but publishes no square footage for this series, so we are not going to invent one. Natural Resources Canada asks for a recognised load calculation such as CSA F280 before a heat pump is selected; your installer runs it on your own rooms.

How well does it heat in a Canadian winter?

The outdoor unit is rated to keep heating down to -25 C (-13 F), and a chassis heater keeps the base pan clear. Output still drops as it gets colder: Natural Resources Canada describes the balance point, the outdoor temperature below which a heat pump can no longer carry the whole load and backup heat takes over. Where that point falls depends on your house, not on the equipment alone, so ask your installer to work it out.