Blast Pro 38,000 BTU 4 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 9K + 9K + 12K
Fast delivery
Arrives quickly and safely
Buyer protection
Covered end to end
Secure packaging
Damage-free guarantee
Ships from
ValuHub Fulfillment
Blast Pro 38,000 BTU 4 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 9K + 9K + 12K
Description
Blast Pro 38,000 BTU 4 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 9K + 9K + 12K
Three 9,000 BTU indoor units and one 12,000 BTU unit share one 38,000 BTU condenser, so the busiest room gets the extra capacity without oversizing the other three. Published ratings are 20 SEER2 on cooling and 9.5 HSPF2 on heating, running R32 refrigerant, with heating listed down to -20°C (-4°F).
One room in the house always runs a couple of degrees out
What usually goes wrong
Three rooms behave and the fourth never quite matches. It might face west, sit over the garage, or have one more window than the others. Turning the whole system harder is an expensive way to fix one room.
How this configuration answers it
The odd room gets a 12,000 BTU head instead of the 9,000 BTU used on the other three, with its own controller to hold it there. Only the zones that are switched on draw from the 38,000 BTU outdoor unit.
Four heads on one condenser is the practical middle ground for a Canadian house with uneven rooms: real heating as well as cooling, and no ductwork to build. Everything indoors connects back to the same 38,000 BTU outdoor unit through its own insulated copper line set.

Everything that arrives on the pallet
Everything in the photo ships together: the 38,000 BTU outdoor unit, four indoor units rated 9,000, 9,000, 9,000 and 12,000 BTU, the coiled copper line sets, drain hose, tape and putty, and the remote and app that drive it. The outdoor unit is the big one in this range at 42.64 x 19.45 x 33.78 in (L x W x H).
What the yellow label says
The EnergyGuide panel in this photo reads 20 SEER2 for cooling and 9.5 HSPF2 for heating, on R32 refrigerant. R32 carries a lower global warming potential than the R410A still common on older equipment. The inverter compressor varies its speed rather than cycling, which is what keeps a room from swinging.


Built for a cold snap
The glow at the base is chassis electrical heating, there to stop ice building in the pan. The manufacturer publishes heating down to -20°C (-4°F) and cooling up to 53°C (127°F). Natural Resources Canada notes heat pumps give less heat as the air gets colder, so plan a backup heat source for the coldest stretch of a Canadian winter.
Eight fan speeds is more useful than it sounds
Mute and low sit below the speeds most units start at, which matters in a room you sleep or work in. The panel lists eight fan speeds and seven modes including ECO, plus a 24 hour timer, 4D swing and a child lock. The 4D swing sends air along the ceiling rather than straight down at the sofa.

What you get
Four zones, one compressor
One 38,000 BTU outdoor unit runs all four indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing to leave alone.
Matching each unit to its room
A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.
Inverter compressor
The compressor varies its speed instead of cycling on and off. Published ratings are 20 SEER2 for cooling and 9.5 HSPF2 for heating on R32 refrigerant.
Built for a Canadian winter
A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -20°C (-4°F) and cooling up to 53°C (127°F).
Line sets and wiring supplied
Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire, plus a 8 ft drain hose. That is the material most quotes list separately, four times over on a system this size.
Electrical supply
The outdoor unit runs on 208-230V 60Hz. This is not a standard 15 amp household outlet. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.
Controls
Wifi app, a remote with a digital display for each zone, and voice control through Alexa or Google Home. A 24 hour timer and a child lock are built in.
Filters you can rinse
The indoor filters pull out, rinse under a tap and go back in. Four heads means four sets, and clean filters are the cheapest way to keep airflow and running cost where they should be.
Specifications
| Zones | 4 (one outdoor unit, four indoor units) |
|---|---|
| Outdoor unit capacity | 38,000 BTU |
| Indoor unit capacities | 9,000, 9,000, 9,000 and 12,000 BTU |
| System type | Ductless heat pump, cooling and heating |
| SEER2 (cooling) | 20 |
| HSPF2 (heating) | 9.5 |
| Refrigerant | R32 |
| Power supply | 208-230V 60Hz |
| Heating range | Down to -20°C (-4°F) |
| Cooling range | Up to 53°C (127°F) |
| Operating modes | 7: auto, cool, heat, dry, fan, ECO, sleep |
| Fan speeds | 8: auto, mute, low, low-mid, mid, mid-high, high, turbo |
| Indoor sound level | From 28 dB |
| Line set supplied | 16 ft per zone, insulated copper (gas and liquid) |
| Communication wire | 19 ft per zone |
| Drain hose | 8 ft per zone |
| Outdoor unit size | 42.64 x 19.45 x 33.78 in (L x W x H) |
| Indoor unit size, 9,000 BTU | 31.93 x 7.48 x 12.05 in (L x W x H) |
| Indoor unit size, 12,000 BTU | 31.93 x 7.48 x 12.05 in (L x W x H) |
| Colour | White |
| Manufacturer SKU | 26783816_Blastpro-38K-19 |
Capacity by zone
How it compares
Three ways people usually fix four uneven rooms in a Canadian home. This is how they differ in practice, not in price.
| This 4 zone system | A window or portable unit per room | Adding central ducted air | |
|---|---|---|---|
| Separate temperature per room | Yes, four independent set points | Yes, but each room needs its own machine | Usually one thermostat for the whole zone |
| Heats as well as cools | Yes, rated to -20°C (-4°F) | Many are cooling only | Depends on the furnace or air handler fitted |
| Ductwork | None, one cored hole per zone | None | Full duct network to every room |
| Machines outside | One outdoor unit | One in every window | One condenser plus the indoor plant |
| Windows stay clear | Yes | No | Yes |
| Who installs it | Licensed HVAC and electrical trades | You do, out of the carton | Licensed trades, often several days on site |
Shipping
Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.
Returns
Return within 14 days of purchase, unused, in original condition and packaging.
Warranty
Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.
Who is this perfect for?
Three bedrooms and a slightly larger main room
The 12,000 BTU zone suits roughly 480 to 600 sq ft and the three 9,000 BTU zones roughly 360 to 450 sq ft each. A common shape for a bungalow or a semi.
Homes with no ducts to extend
Older houses, additions, attic conversions and finished basements rarely have duct where it is needed. Four zones from one outdoor unit avoids opening up ceilings.
Households that want heat as well as cooling
This is a heat pump, not a cooling only air conditioner. It carries a 9.5 HSPF2 heating rating and a chassis electrical heater on the outdoor unit for cold weather.

What we stand behind
- Ships from a Canadian warehouse, with free shipping on orders over $150
- 14 day returns on unused items in original condition and packaging
- Covered by the manufacturer's own warranty for material and manufacturing defects
- Line sets, communication wire and a controller for every one of the four zones are in the box
Frequently asked questions
How much space will each indoor unit cover?
Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Poor insulation, large west facing windows or a 9 ft ceiling all push the figure up.
The four indoor units add up to 39,000 BTU but the outdoor unit is 38,000 BTU. Is that a mistake?
No. On any multi zone system the indoor ratings are not meant to be added together, and multi zone sizing guides say so plainly. The 38,000 BTU figure is what the outdoor unit can deliver at one time, shared among whichever zones are calling for it. Four rooms rarely peak at the same moment, which is why this combination is offered.
How cold can it get outside before it stops heating?
The manufacturer rates low ambient heating down to -20°C (-4°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most newer units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.
Can I install this myself in Canada, and does it run on a normal outlet?
No on both counts. The outdoor unit runs on 208-230V 60Hz, so it needs its own branch circuit and an electrician, not a wall socket. Refrigerant work is also regulated: Ontario, for example, states that only a certified technician may remove, discharge, handle and dispose of refrigerants including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of that. Other provinces have their own halocarbon rules, and the federal Code of Practice says the same thing in plainer terms.