Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 2
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 3
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 4
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 5
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 6
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 7
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 8
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 9
-30%
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 2
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 3
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 4
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 5
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 6
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 7
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 8
Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K view 9

Blast Pro 38,000 BTU 3 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 9K + 9K

sold in last days
Regular price $5,227.00 Sale price $3,659.00
Save $1,568.00
In Stock

Fast delivery

Arrives quickly and safely

Buyer protection

Covered end to end

Secure packaging

Damage-free guarantee

Ships from

ValuHub Fulfillment

Blast Pro 38000 BTU 3 Zone 20 SEER2 Mini Split AC with Heat Pump 9K + 9K + 9K

Blast Pro 38,000 BTU 3 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 9K + 9K

$3,659.00
Description

Blast Pro 38,000 BTU 3 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 9K + 9K

Room-by-room control comes from three indoor units at 9,000, 9,000 and 9,000 BTU, all piped back to one 38,000 BTU condenser. Cooling is rated 20 SEER2 and heating 9.5 HSPF2, on R32 refrigerant, with a chassis heater that keeps the outdoor unit working to -20°C (-4°F).

20 SEER2 coolingHeating rated to -20°CR32 refrigerantWifi, remote and voice control

One thermostat, three people who disagree with it

What usually goes wrong

A single thermostat averages the whole house and reads one room. Somebody is always too warm or too cold. Closing vents to rebalance a room just moves the problem somewhere else and strains the blower.

How this configuration answers it

Three zones measure and correct their own space. The 9,000 BTU unit can hold one room cool while the 9,000 BTU unit heats another, and both report back to the same 38,000 BTU outdoor unit without fighting each other.

Multi-zone means one compressor outside and three indoor units inside, each on its own controller. You heat or cool only the rooms you are actually using, and the rest of the house stays as it was.

Complete three zone kit photographed together: outdoor condenser, three indoor units, remotes, phone app and coiled line sets

One outdoor unit, three indoor units

The photo has the complete system in it: a 38,000 BTU condenser for outside, three wall units of 9,000, 9,000 and 9,000 BTU for inside, three remotes and the copper, wire and sundries that connect them. Nothing here is sold separately as an accessory pack.

Phone, remote or voice

The system connects to wifi, so each zone can be checked and changed from the app while you are out. It also answers to Amazon Alexa and Google Home, and every indoor unit still ships with a physical remote for anyone who would rather press a button.

Two people on a sofa looking at the control app on a phone, with an indoor unit blowing air and the Alexa and Google Home compatibility badges shown
House cutaway showing separately controlled kitchen, bathroom, bedroom and living room, each labelled with its own temperature

Rooms behave differently, so treat them differently

A kitchen throws heat, a north bedroom loses it, and a bathroom needs neither for most of the day. Three independent zones let each one settle where it should instead of averaging the whole floor into one compromise.

One box on the outside wall

Three separate systems would mean three condensers along the side of the house. This is one, with the refrigerant lines running up inside the wall to each zone. It matters more than it sounds when the side yard is narrow or the neighbours are close.

Modern two-storey house at dusk with a single outdoor condenser beside it and the refrigerant lines traced up to three rooms

What you get

Three zones, one compressor

One 38,000 BTU outdoor unit runs all three indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing.

Matching each unit to its room

A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). Each 9,000 BTU unit suits roughly 360 to 450 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.

Inverter compressor

The compressor varies its speed instead of cycling on and off. Published ratings are 20 SEER2 for cooling and 9.5 HSPF2 for heating.

Built for a Canadian winter

A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -20°C (-4°F) and cooling up to 53°C (127°F).

Line sets and wiring supplied

Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire, plus a 8 ft drain hose. That is the material most quotes list separately.

Electrical supply

The outdoor unit runs on 208/230V 60Hz. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.

Controls

Wifi app, a remote with a digital display for each zone, Amazon Alexa and Google Home.

Filters you can rinse

The indoor filters pull out, rinse under a tap and go back in. Clean filters are the cheapest way to keep airflow and running cost where they should be.

Specifications

Blast Pro, 38,000 BTU outdoor unit with 9,000, 9,000 and 9,000 BTU indoor units
Zones 3 (one outdoor unit, three indoor units)
Outdoor unit capacity 38,000 BTU
Indoor unit capacities 9,000, 9,000 and 9,000 BTU
System type Ductless heat pump, cooling and heating
SEER2 (cooling) 20
HSPF2 (heating) 9.5
Refrigerant R32
Power supply 208/230V 60Hz
Heating range Down to -20°C (-4°F)
Cooling range Up to 53°C (127°F)
Operating modes 7: auto, cool, heat, dry, fan, ECO, sleep
Fan speeds 8: auto, mute, low, low-mid, mid, mid-high, high, turbo
Indoor sound level From 28 dB
Line set supplied 16 ft per zone, insulated copper (gas and liquid)
Communication wire 19 ft per zone
Drain hose 8 ft per zone
Outdoor unit size 42.64 x 19.45 x 33.78 in (L x W x H)
Indoor unit size, 9,000 BTU 31.93 x 7.48 x 12.05 in (L x W x H)
Colour White
Manufacturer SKU 68986948_Blastpro-38K-8

Capacity by zone

Rated capacity of each zone in BTU Zone 19,000 BTUZone 29,000 BTUZone 39,000 BTUOutdoor unit rated 38,000 BTU
Rated capacity of each indoor unit in this configuration, drawn to the same scale, with the outdoor unit total underneath. At the common rule of thumb of 20 to 25 BTU per square foot: Each 9,000 BTU unit suits roughly 360 to 450 sq ft. Use CSA F280-12 for a real load calculation.

How it compares

Three ways people usually fix uneven rooms in a Canadian home. This is how they differ in practice, not in price.

  This 3 zone system A window or portable unit per room Adding central ducted air
Separate temperature per room Yes, three independent set points Yes, but each room needs its own machine Usually one thermostat for the whole zone
Heats as well as cools Yes, rated to -20°C (-4°F) Many are cooling only Depends on the furnace or air handler fitted
Ductwork None, one cored hole per zone None Full duct network to every room
Indoor equipment on show Three slim units mounted high on a wall A machine in every window Vents and returns
Windows stay clear Yes No Yes
Who installs it Licensed HVAC and electrical trades You do, out of the carton Licensed trades, often several days on site

Shipping

Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.

Returns

Return within 14 days of purchase, unused, in original condition and packaging.

Warranty

Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.

Who is this perfect for?

Three rooms of similar size

All three units are 9,000 BTU, so this suits three comparable spaces of roughly 360 to 450 sq ft each: bedrooms, a home office, a finished basement room.

Homes with no ducts to extend

Older houses, additions, attic conversions and finished basements rarely have ducts where they are needed. Three zones from one outdoor unit avoids opening up ceilings.

People who want heat as well as cooling

This is a heat pump, not a cooling-only air conditioner. It carries an HSPF2 heating rating of 9.5 and a chassis heater for winter operation.

Dimension chart showing the size of every indoor unit and outdoor unit in the range, with drawings of both units

What we stand behind

  • Ships from a Canadian warehouse, with free shipping on orders over $150
  • 14 day returns on unused items in original condition and packaging
  • Covered by the manufacturer's own warranty for material and manufacturing defects
  • Line sets, communication wire and a controller for every zone are in the box

Frequently asked questions

How much space will each indoor unit cover?

Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. Each 9,000 BTU unit suits roughly 360 to 450 sq ft. Poor insulation, big west-facing windows or a 9 ft ceiling all push that figure up.

The three indoor units add up to 27,000 BTU and the outdoor unit is rated 38,000 BTU. Why the gap?

Multi-zone outdoor units come in fixed sizes and the indoor combinations are built around them, so the totals rarely land exactly. The spare capacity is not wasted: the inverter compressor simply runs at a lower speed, which is where a modulating system gets its efficiency. Either way, do not add the indoor ratings together to judge the system. The 38,000 BTU figure is what can be delivered at one time, shared among the zones that are calling.

How cold can it get outside before it stops heating?

The manufacturer rates low ambient heating down to -20°C (-4°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.

Can I install this myself in Canada?

Plan on a licensed installer. In Ontario, for example, the province states that by law only a certified technician may remove, discharge, handle and dispose of refrigerants, including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of the refrigerant certificate. Other provinces have their own halocarbon rules. The federal Code of Practice says the same thing in plainer terms: the technician doing work that could release refrigerant must hold the proper environmental certification. The 208/230V 60Hz power supply also means an electrician and a dedicated circuit.