Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 2
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 3
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 4
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 5
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 6
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 7
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 8
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 9
-32%
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 2
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 3
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 4
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 5
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 6
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 7
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 8
Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K view 9

Blast Pro 38,000 BTU 2 Zone Mini Split Heat Pump, 20 SEER2, 12K + 18K

sold in last days
Regular price $4,741.00 Sale price $3,219.00
Save $1,522.00
In Stock

Fast delivery

Arrives quickly and safely

Buyer protection

Covered end to end

Secure packaging

Damage-free guarantee

Ships from

ValuHub Fulfillment

Blast Pro 38000 BTU 2 Zone 20 SEER2 Mini Split AC with Heat Pump-12K + 18K

Blast Pro 38,000 BTU 2 Zone Mini Split Heat Pump, 20 SEER2, 12K + 18K

$3,219.00
Description

Blast Pro 38,000 BTU 2 Zone Mini Split Heat Pump, 20 SEER2, 12K + 18K

Room by room control without ducts: a 12,000 BTU head rated for up to 750 sq ft and an 18,000 BTU head rated for up to 1,250 sq ft fed by one 38,000 BTU outdoor unit, each with its own remote, its own fan speed and its own target temperature.

38,000 BTU across 2 zones12,000 BTU + 18,000 BTU unitsHeats to -20 C (-4 F)

One large room, one small room, no compromise

What usually goes wrong

One big room and one small room on the same system usually means a compromise. Size for the big room and the small one overshoots and cycles. Size for the small one and the big room never catches up on the hottest or coldest days.

How this configuration answers it

This configuration is deliberately uneven: an 18,000 BTU unit for the larger space and a 12,000 BTU unit for the smaller one, both fed by the same 38,000 BTU condenser. Each is sized to its own room instead of splitting one capacity down the middle.

The point of a two zone system is that the second room is not an afterthought. Each indoor unit has its own thermostat setting and its own fan, and the inverter outside ramps up and down to match whatever the pair is asking for rather than cycling flat out.

Two white wall heads stacked above the outdoor condenser, with a coiled line set, drain hose, remote, accessories and a phone showing the app

What arrives on the pallet

The carton holds one outdoor condenser, two wall mounted heads, and two 16 ft gas line sets and two 16 ft liquid line sets, two 19 ft communication wires, two 8 ft drain hoses, two remotes with holders, wall sleeves, caps, tape, putty, screw kits and four mounting foot pads. The outdoor unit measures 42.64" x 19.45" x 33.78" and weighs 148.8 lb. The indoor units are a 12,000 BTU at 19.8 lb and an 18,000 BTU at 20.9 lb, measuring 31.93" x 7.48" x 12.05" and 35.83" x 7.68" x 12.01".

How much room each unit covers

The 12,000 BTU unit is published for up to 750 sq ft and the 18,000 BTU unit for up to 1,250 sq ft, at 342 and 617 CFM of airflow. Those are the manufacturer's own figures for a room with average ceilings and normal insulation. Natural Resources Canada asks for a recognised load calculation, CSA F280, before equipment is picked, because a leaky 1950s bungalow and a new build of the same floor area do not need the same capacity. Take both numbers to your installer and let the calculation settle it.

Cutaway view of a modern two storey house with the outdoor unit at the side and refrigerant lines running up to two highlighted rooms
The outdoor condenser standing in snow and ice with the chassis heater glowing orange underneath, and the cooling and heating temperature limits printed beside it

Winter output and the balance point

Heating output on any air source heat pump falls as the outdoor air gets colder. The manufacturer rates this outdoor unit to keep heating down to -20 C (-4 F) and to keep cooling up to 53 C (127 F), and fits a chassis heater that keeps the base pan from icing up. What that figure does not tell you is your balance point, the outdoor temperature below which the heat pump can no longer carry the load on its own. Natural Resources Canada describes that point and the backup heat that takes over below it; your installer works it out for your house.

Quiet running, and how you set it

Both heads are rated as low as 28 dB, with 7 modes (auto, cool, heat, dry, fan, ECO and sleep) and 8 fan speeds from mute to turbo, a 24 hour timer, a child lock, 4D auto swing and a self clean cycle that dries the coil after a run. Filters pull out and wash under the tap. Set it from the wifi app, the remote, or by voice through Alexa or Google Assistant.

A wall head blowing air across a curtained room beside a hand holding the remote, with the fan speed, mode, timer, swing and child lock icons listed

What you get

Two zones, two set temperatures

Each indoor unit has its own controller and its own target temperature, so one room can sit at 20 C while the other sits at 23 C, from one outdoor unit and one circuit. Both zones share that one compressor: output is divided when they call at once, and the manufacturer does not publish simultaneous heating and cooling for this system, so do not plan on it.

Inverter compressor

Rated 20 SEER2 for cooling and 9.5 HSPF2 for heating. The compressor ramps its speed up and down to hold a temperature instead of switching hard on and off.

R32 refrigerant

R32 has a global warming potential of 675 against R410A's 2,088, and is rated A2L for low toxicity and mild flammability.

Chassis heater on the outdoor unit

Rated to keep heating down to -20 C (-4 F) and cooling up to 53 C (127 F). The heated base pan is there to stop meltwater freezing under the coil during a defrost cycle.

App, remote or voice

Wifi built in, with Alexa and Google Assistant support, a remote for each indoor unit, and a 24 hour timer.

Line sets in the box

Two 16 ft copper line sets, communication wire, drain hoses and mounting hardware ship with the system. The manufacturer does not publish a maximum line length for this model, so have your installer confirm the runs before the holes are cut.

208/230V power

This is not a plug in appliance. It needs a dedicated 208/230V, 60 Hz circuit and a disconnect at the outdoor unit, wired by an electrician. The indoor units are fed from the outdoor unit, not from separate outlets.

Professional installation required

The manufacturer states that installation by a professional technician is required for this system. Refrigerant handling is regulated province by province in Canada.

Specifications

Blast Pro 38,000 BTU two zone system, 12K + 18K indoor units
Zones 2 (one outdoor unit, two independently controlled indoor units)
Outdoor unit capacity 38,000 BTU
Indoor units one 12,000 BTU and one 18,000 BTU wall mounted head
SEER2 (cooling) 20
HSPF2 (heating) 9.5
Refrigerant R32
Power supply 208/230V, 60 Hz
Operating range heating down to -20 C (-4 F), cooling up to 53 C (127 F)
Temperature setting range 60 F to 88 F
Outdoor unit dimensions 42.64" x 19.45" x 33.78" (L x W x H)
Outdoor unit weight 148.8 lb
Indoor unit dimensions 12,000 BTU: 31.93" x 7.48" x 12.05", 19.8 lb. 18,000 BTU: 35.83" x 7.68" x 12.01", 20.9 lb
Coverage published 12,000 BTU up to 750 sq ft, 18,000 BTU up to 1,250 sq ft
Dehumidification 81.2 pints a day and 111.6 pints a day
Maximum airflow 342 CFM and 617 CFM
Indoor sound level as low as 28 dB
Line set diameters liquid 1/4", gas 3/8"
Line sets included two 16 ft copper line sets
Colour White
Manufacturer SKU Blastpro-38K-3

What each zone is rated to cover

Coverage area published for each indoor unit Zone 112,000 BTUup to 750 sq ftZone 218,000 BTUup to 1,250 sq ft0 sq ft1,500 sq ft
Coverage figures are the manufacturer's own published numbers for each indoor unit size. They are a starting point, not a design. Natural Resources Canada asks for a recognised load calculation such as CSA F280 before equipment is chosen, and ceiling height, insulation, window area and how many walls face outside all move the answer.

How it compares

Three other ways people fix a room that is too hot or too cold, set beside this one. The comparisons are general category differences, not tests of named products.

Ā  This 2 zone system Window or portable units Central air or furnace alone Adding ducts to the room
Rooms controlled separately Two, each with its own set temperature Each unit is separate but only cools One thermostat sets the whole house Depends on dampers and zoning
Heating as well as cooling Yes, heat pump rated to -20 C (-4 F) Cooling only on most units Yes, from the existing furnace Yes, from the existing furnace
Window space Nothing in the window Blocks a window through the season Nothing in the window Nothing in the window
Construction work Wall penetrations for the line sets None None Framing, drywall and finishing
Who can install it Licensed HVAC trade, refrigerant handling is regulated Homeowner Licensed trade for the equipment Licensed trade
Seasonal storage Stays in place year round Hauled out and stored every autumn Stays in place Stays in place

Shipping

Ships from a Canadian warehouse. Free shipping on orders over $150; some remote areas, PO boxes and surcharge regions may cost extra.

Returns

Return within 14 days of purchase, unused, in original condition and packaging.

Warranty

Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.

Who is this perfect for?

Houses with no ductwork

Older homes on hot water or electric baseboard get cooling and heat pump heating without a duct being cut, since the refrigerant lines need only a small wall penetration.

One big space plus one small one

An 18,000 BTU wall mounted head and a 12,000 BTU wall mounted head let a large open area and a single room each get what they need from one outdoor unit.

Owners planning a proper install

Refrigerant work is regulated in every province, and the manufacturer requires a professional technician. This suits buyers who already have an HVAC contractor and an electrician lined up.

Flat lay of the carton contents: outdoor unit, two indoor heads, two remotes with holders, gas and liquid copper pipes, communication wires, drain hoses, mounting foot pads, screw kits, putty, tape, wall caps and wall sleeves

What we stand behind

  • One outdoor unit, two indoor units and two 16 ft line sets in the box
  • Ships from a Canadian warehouse, free shipping over $150
  • 14 day returns on unused product in original packaging
  • Covered by the manufacturer's warranty for material and manufacturing defects

Frequently asked questions

Can a homeowner install this, or is a licensed installer required?

The manufacturer states that professional installation is required for this system. In Canada, handling refrigerant is regulated province by province, and provinces require trained service providers for installing, servicing and decommissioning equipment that contains halocarbons. Ontario, as one example, restricts removing, discharging and disposing of refrigerants to certified technicians and requires a separate trade Certificate of Qualification to actually work on the equipment. Budget for an HVAC contractor and an electrician.

What electrical supply does it need?

A dedicated 208/230V, 60 Hz circuit, not a wall outlet. On a multi zone system the indoor units are powered from the outdoor unit rather than from their own plugs, and code calls for a disconnect at the outdoor unit. An electrician sizes the breaker and wire from the unit's own nameplate.

What size room does each indoor unit suit?

The manufacturer publishes up to 750 sq ft for the 12,000 BTU unit and up to 1,250 sq ft for the 18,000 BTU unit. Treat those as a starting point. Natural Resources Canada asks for a recognised load calculation such as CSA F280 before equipment is selected, since ceiling height, insulation, air leakage and window area all change the answer for the same floor area.

How well does it heat in a Canadian winter?

The outdoor unit is rated to keep heating down to -20 C (-4 F), and a chassis heater keeps the base pan clear. Output still drops as it gets colder: Natural Resources Canada describes the balance point, the outdoor temperature below which a heat pump can no longer carry the whole load and backup heat takes over. Where that point falls depends on your house, not on the equipment alone, so ask your installer to work it out.