Three 7,000 BTU indoor units and one 9,000 BTU unit share one 36,000 BTU condenser, so the busiest room gets the extra capacity without oversizing the other three. Published ratings are 23 SEER2 on cooling and 10 HSPF2 on heating, running R32 refrigerant, with heating listed down to -25°C (-13°F).
Buying four identical heads and hoping for the best
What usually goes wrong
Most packaged multi zone kits come with four matched heads because it is simpler to stock. If one of your four rooms is noticeably bigger, that room stays behind all summer and all winter.
How this configuration answers it
This combination is not matched on purpose: three 7,000 BTU indoor units for the ordinary rooms and one 9,000 BTU unit for the larger one. Only the zones that are switched on draw from the 36,000 BTU outdoor unit.
This is the size of system people reach for when three zones stopped being enough. One box outside, four rooms inside, and one cored hole per room instead of a duct chase. Everything indoors connects back to the same 36,000 BTU outdoor unit through its own insulated copper line set.

What is actually in the cartons
The chart counts it out: one outdoor unit, four indoor units, and for every zone a remote, a wall sleeve, a drain hose, a copper line set, a mounting plate, communication wire and a screw kit. Tape, putty and wall caps come eight up. Line sets are the item most quotes price separately, and there are four of them here, 16 ft each.
The number that matters in February
That orange glow along the base is the chassis heater keeping the pan clear of ice so the unit can still shed meltwater. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 52°C (125°F). Natural Resources Canada notes that heat pumps lose capacity as it gets colder, so keep a backup heat source for the worst nights.


Control from the sofa or from work
Each zone answers to the app as well as its own remote, so you can start the living room before you get home and leave the spare bedroom off. The app screen in the photo shows a single zone with its mode, fan speed and set point. Nothing here needs a smart speaker: the app and the remote do the work.
The five minute job that keeps it cheap to run
The front panel lifts and the filters slide out. Rinse them under a tap, let them dry, put them back. Four indoor units means four sets to do, and dirty filters are the most common reason a zone stops keeping up and starts costing more to run.

What you get
Four zones, one compressor
One 36,000 BTU outdoor unit runs all four indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing to leave alone.
Matching each unit to its room
A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). On that basis a 7,000 BTU unit suits roughly 280 to 350 sq ft and a 9,000 BTU unit suits roughly 360 to 450 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.
Inverter compressor
The compressor varies its speed instead of cycling on and off. Published ratings are 23 SEER2 for cooling and 10 HSPF2 for heating on R32 refrigerant.
Built for a Canadian winter
A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 52°C (125°F).
Line sets and wiring supplied
Each zone gets a 16 ft insulated copper line set and 13 ft of communication wire, plus a 6.5 ft drain hose. That is the material most quotes list separately, four times over on a system this size.
Electrical supply
The outdoor unit runs on 208-230V~60Hz, single phase. This is not a standard 15 amp household outlet. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.
Controls
Wifi app plus a remote with a digital display for each zone, and a 24 hour timer. No smart speaker is needed to run it.
Filters you can rinse
The indoor filters pull out, rinse under a tap and go back in. Four heads means four sets, and clean filters are the cheapest way to keep airflow and running cost where they should be.
Specifications
| Zones | 4 (one outdoor unit, four indoor units) |
|---|---|
| Outdoor unit capacity | 36,000 BTU |
| Indoor unit capacities | 7,000, 7,000, 7,000 and 9,000 BTU |
| System type | Ductless heat pump, cooling and heating |
| SEER2 (cooling) | 23 |
| HSPF2 (heating) | 10 |
| Refrigerant | R32 |
| Power supply | 208-230V~60Hz, single phase |
| Heating range | Down to -25°C (-13°F) |
| Cooling range | Up to 52°C (125°F) |
| Operating modes | 6: auto, cool, heat, dry, fan, sleep |
| Fan speeds | 5: auto, low, mid, high, strong |
| Indoor sound level | 30 dB at 7,000 BTU, 30 dB at 9,000 BTU |
| Certification | ENERGY STAR, ETL and AHRI |
| Line set supplied | 16 ft per zone, insulated copper (gas and liquid) |
| Communication wire | 13 ft per zone |
| Drain hose | 6.5 ft per zone |
| Outdoor unit size | 41.2 x 17.9 x 31.8 in (L x W x H) |
| Indoor unit size, 7,000 BTU | 31 x 7.8 x 11.5 in (L x W x H) |
| Indoor unit size, 9,000 BTU | 31 x 7.8 x 11.5 in (L x W x H) |
| Colour | White |
| Manufacturer SKU | 981354762_UltrEco-36K-46 |
Capacity by zone
How it compares
Three ways people usually fix four uneven rooms in a Canadian home. This is how they differ in practice, not in price.
| This 4 zone system | A window or portable unit per room | Adding central ducted air | |
|---|---|---|---|
| Separate temperature per room | Yes, four independent set points | Yes, but each room needs its own machine | Usually one thermostat for the whole zone |
| Heats as well as cools | Yes, rated to -25°C (-13°F) | Many are cooling only | Depends on the furnace or air handler fitted |
| Ductwork | None, one cored hole per zone | None | Full duct network to every room |
| Machines outside | One outdoor unit | One in every window | One condenser plus the indoor plant |
| Windows stay clear | Yes | No | Yes |
| Who installs it | Licensed HVAC and electrical trades | You do, out of the carton | Licensed trades, often several days on site |
Shipping
Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.
Returns
Return within 14 days of purchase, unused, in original condition and packaging.
Warranty
Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.
Who is this perfect for?
Three bedrooms and a slightly larger main room
The 9,000 BTU zone suits roughly 360 to 450 sq ft and the three 7,000 BTU zones roughly 280 to 350 sq ft each. A common shape for a bungalow or a semi.
Homes with no ducts to extend
Older houses, additions, attic conversions and finished basements rarely have duct where it is needed. Four zones from one outdoor unit avoids opening up ceilings.
Households that want heat as well as cooling
This is a heat pump, not a cooling only air conditioner. It carries a 10 HSPF2 heating rating and a chassis electrical heater on the outdoor unit for cold weather.

What we stand behind
- Ships from a Canadian warehouse, with free shipping on orders over $150
- 14 day returns on unused items in original condition and packaging
- Covered by the manufacturer's own warranty for material and manufacturing defects
- Line sets, communication wire and a controller for every one of the four zones are in the box
Frequently asked questions
How much space will each indoor unit cover?
Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. On that basis a 7,000 BTU unit suits roughly 280 to 350 sq ft and a 9,000 BTU unit suits roughly 360 to 450 sq ft. Poor insulation, large west facing windows or a 9 ft ceiling all push the figure up.
Can all four zones run at the same time?
Yes. The four indoor units here total 30,000 BTU and the outdoor unit is rated 36,000 BTU, so the outdoor unit can cover every zone calling at once. Sizing each head to its own room still matters more than the total, because an oversized head in a small room short cycles.
How cold can it get outside before it stops heating?
The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most newer units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.
Can I install this myself in Canada, and does it run on a normal outlet?
No on both counts. The outdoor unit runs on 208-230V~60Hz, single phase, so it needs its own branch circuit and an electrician, not a wall socket. Refrigerant work is also regulated: Ontario, for example, states that only a certified technician may remove, discharge, handle and dispose of refrigerants including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of that. Other provinces have their own halocarbon rules, and the federal Code of Practice says the same thing in plainer terms.