X-Pro 35,000 BTU 3 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 24K
Fast delivery
Arrives quickly and safely
Buyer protection
Covered end to end
Secure packaging
Damage-free guarantee
Ships from
ValuHub Fulfillment
X-Pro 35,000 BTU 3 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 24K
Description
X-Pro 35,000 BTU 3 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 24K
Split across three zones at 9,000, 9,000 and 24,000 BTU, this 35,000 BTU heat pump cools in summer and heats in winter. The manufacturer rates it 22.5 SEER2 for cooling and 10 HSPF2 for heating, with R454B refrigerant and low ambient heating to -25°C (-13°F).
One thermostat for a floor that never behaves
What usually goes wrong
A single thermostat reads one room and averages the rest. Closing vents to rebalance a space just moves the problem and strains the blower. Somebody is always adjusting it and somebody else is always changing it back.
How this configuration answers it
Three zones, three wall thermostats, three set points. The 24,000 BTU handler can cool one space while the 9,000 BTU handler heats another, both drawing from the same 35,000 BTU outdoor unit.
The point of a three zone system is that rooms stop arguing with each other. One space can sit at 20°C while the next sits at 24°C, and neither one has a window unit in it.

The kit, before any of it disappears into a ceiling
Once it is installed you will never see most of this again. Three beige ducted air handlers at 9,000, 9,000 and 24,000 BTU, one 35,000 BTU outdoor unit, insulated copper for each zone and three wall thermostats, which are the only parts that stay in sight.
What happens when it gets properly cold
The outdoor unit carries a chassis electrical heater, which keeps the base pan clear so meltwater does not freeze under the coil. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F). Natural Resources Canada notes most air source heat pumps stop somewhere between -15°C and -25°C, so plan on a backup heat source for the coldest nights.


Reading the yellow label
The EnergyGuide panel in this photo is the honest summary: 22.5 SEER2 on cooling, 10 HSPF2 on heating, with R454B refrigerant in the system. The graph beside it shows why an inverter holds temperature better than a fixed-speed compressor that only knows on and off. It carries ETL and AHRI certification.
Heating and cooling through the same grilles
Nothing changes in the room between seasons: the same ducted handler and the same grilles carry cool air in summer and warm air in winter. Seven modes, eight fan speeds, a 24 hour timer, a child lock and a self-clean function are all on the control.

What you get
Three zones, one compressor
One 35,000 BTU outdoor unit runs all three ducted air handlers. Each zone starts, stops and holds its own temperature, so an empty room costs nothing.
Matching each unit to its room
A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 24,000 BTU unit suits roughly 960 to 1,200 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.
Inverter compressor
The compressor varies its speed instead of cycling on and off. Published ratings are 22.5 SEER2 for cooling and 10 HSPF2 for heating.
Built for a Canadian winter
A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F).
Line sets and wiring supplied
Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire. That is the material most quotes list separately.
Electrical supply
The outdoor unit runs on 208-230V 60Hz. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.
Controls
A wall thermostat for each zone, plus a handheld remote, the phone app, Amazon Alexa and Google Home.
Nothing on the wall
The air handlers sit above a ceiling or inside a bulkhead and feed short duct runs to grilles. Only the supply and return grilles are visible in the room.
Specifications
| Zones | 3 (one outdoor unit, three ducted air handlers) |
|---|---|
| Outdoor unit capacity | 35,000 BTU |
| Air handler capacities | 9,000, 9,000 and 24,000 BTU |
| System type | Concealed ducted heat pump, cooling and heating |
| SEER2 (cooling) | 22.5 |
| HSPF2 (heating) | 10 |
| Refrigerant | R454B |
| Power supply | 208-230V 60Hz |
| Heating range | Down to -25°C (-13°F) |
| Cooling range | Up to 55°C (131°F) |
| Operating modes | 7: auto, cool, heat, dry, fan, ECO, sleep |
| Fan speeds | 8: auto, mute, low, low-mid, mid, mid-high, high, turbo |
| Indoor sound level | From 28 dB |
| Certification | ETL and AHRI |
| Line set supplied | 16 ft per zone, insulated copper (gas and liquid) |
| Communication wire | 19 ft per zone |
| Outdoor unit size | 42.28 x 18.43 x 33.58 in (L x W x H) |
| Colour | White outdoor unit, beige ducted air handlers |
| Manufacturer SKU | 25437573_X-Pro-DC-35K-11 |
Capacity by zone
How it compares
Three ways people usually fix uneven rooms in a Canadian home. This is how they differ in practice, not in price.
| This 3 zone system | A window or portable unit per room | Adding central ducted air | |
|---|---|---|---|
| Separate temperature per room | Yes, three independent set points | Yes, but each room needs its own machine | Usually one thermostat for the whole zone |
| Heats as well as cools | Yes, rated to -25°C (-13°F) | Many are cooling only | Depends on the furnace or air handler fitted |
| Ductwork | Short runs from each concealed air handler to its grilles | None | Full duct network to every room |
| Indoor equipment on show | Supply and return grilles only | A machine in every window | Vents and returns |
| Windows stay clear | Yes | No | Yes |
| Who installs it | Licensed HVAC and electrical trades | You do, out of the carton | Licensed trades, often several days on site |
Shipping
Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.
Returns
Return within 14 days of purchase, unused, in original condition and packaging.
Warranty
Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.
Who is this perfect for?
A big room plus two ordinary ones
The 24,000 BTU unit is sized for an open living and dining space, roughly 960 to 1,200 sq ft. The other two zones cover normal bedrooms without oversizing them.
Rooms that should not show the equipment
Tall-window living rooms, heritage interiors, offices and dining rooms all look better without a unit on the wall. The handler hides in a ceiling void and only the grilles are visible.
People who want heat as well as cooling
This is a heat pump, not a cooling-only air conditioner. It carries an HSPF2 heating rating of 10 and a chassis heater for winter operation.

What we stand behind
- Ships from a Canadian warehouse, with free shipping on orders over $150
- 14 day returns on unused items in original condition and packaging
- Covered by the manufacturer's own warranty for material and manufacturing defects
- Line sets, communication wire and a controller for every zone are in the box
Frequently asked questions
How much space will each indoor unit cover?
Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 24,000 BTU unit suits roughly 960 to 1,200 sq ft. Poor insulation, big west-facing windows or a 9 ft ceiling all push that figure up.
The three indoor units add up to 42,000 BTU but the outdoor unit is 35,000 BTU. Is that a mistake?
No. On any multi-zone system the indoor ratings are not meant to be added together, and sizing guides for multi-zone equipment say so plainly. The 35,000 BTU figure is what the outdoor unit can deliver at one time, and it is shared among whichever zones are calling for it. Three rooms rarely peak at the same moment, which is why this combination is offered.
How cold can it get outside before it stops heating?
The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.
Can I install this myself in Canada?
Plan on a licensed installer. In Ontario, for example, the province states that by law only a certified technician may remove, discharge, handle and dispose of refrigerants, including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of the refrigerant certificate. Other provinces have their own halocarbon rules. The federal Code of Practice says the same thing in plainer terms: the technician doing work that could release refrigerant must hold the proper environmental certification. The 208-230V 60Hz power supply also means an electrician and a dedicated circuit.




















