Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 2
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 3
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 4
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 5
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 6
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 7
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 8
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 9
-30%
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 2
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 3
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 4
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 5
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 6
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 7
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 8
Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K view 9

Blast Pro 38,000 BTU 4 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 12K + 12K + 12K

sold in last days
Regular price $6,112.00 Sale price $4,279.00
Save $1,833.00
In Stock

Fast delivery

Arrives quickly and safely

Buyer protection

Covered end to end

Secure packaging

Damage-free guarantee

Ships from

ValuHub Fulfillment

Blast Pro 38000 BTU 4 Zone 20 SEER2 Mini Split AC with Heat Pump-9K + 12K + 12K + 12K

Blast Pro 38,000 BTU 4 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 12K + 12K + 12K

$4,279.00
Description

Blast Pro 38,000 BTU 4 Zone Mini Split Heat Pump, 20 SEER2, Wifi, 9K + 12K + 12K + 12K

Three of the four indoor units are rated 12,000 BTU and the fourth is smaller at 9,000 BTU, with one 38,000 BTU condenser behind all of them. Published ratings are 20 SEER2 on cooling and 9.5 HSPF2 on heating, running R32 refrigerant, with heating listed down to -20°C (-4°F).

20 SEER2 coolingHeating rated to -20°CR32 refrigerantWifi, remote and voice control

The fourth room is the leftover one

What usually goes wrong

A den, a nursery or a converted box room is usually the room nobody plans for. It ends up with a portable unit on the floor, a trailing hose and a window propped open around it.

How this configuration answers it

This configuration gives it a proper zone of its own at 9,000 BTU, alongside three 12,000 BTU indoor units for the main rooms. Only the zones that are switched on draw from the 38,000 BTU outdoor unit.

Four separate heads and one outdoor unit is the usual answer for a house with no ducts worth extending: an older home, a finished basement, an addition or an attic conversion. Everything indoors connects back to the same 38,000 BTU outdoor unit through its own insulated copper line set.

A two storey house at dusk with four rooms tinted green, blue, purple and teal, refrigerant lines running down the wall to a single white outdoor unit beside the driveway

Four rooms, one box outside

The tinted rooms are the four zones and the blue line tracing down the wall is the refrigerant run. One outdoor unit sits at the side of the house instead of four window boxes across the front. Each zone needs a small cored hole and a tidy line cover, not a duct chase.

What is actually in the cartons

Counted out, it is four indoor units, one outdoor unit, four remotes with holders, four gas pipes and four liquid pipes at 16 ft each, four communication wires, four drain hoses, four wall sleeves and four screw kits, with tape, putty and wall caps supplied eight up. The copper is the expensive part and it is already in the box.

Package contents chart showing four indoor units, one outdoor unit, four remotes, four gas and four liquid copper pipes, four communication wires, four drain hoses, four wall sleeves, eight rolls of tape, eight putty packs and eight wall caps
A couple sitting on a sofa looking at a phone app, beside a wall mounted indoor unit blowing air, with Amazon Alexa and Google Home compatibility badges

Phone, remote or voice

Every zone answers three ways: the app on your phone, the handset that ships with each indoor unit, or a voice command through Alexa or Google Home. The app screen in the photo shows one zone at a time, which is how you end up running two zones and leaving two off without thinking about it.

One house, four set points

Four rooms, four numbers, one outdoor unit. The drawing shows a kitchen, a dining room, a study and a bedroom each holding their own temperature. A room nobody is in can be switched off entirely, which is the part a single whole house thermostat cannot do.

Cutaway drawing of a house with indoor units in four rooms set to 21, 22, 21 and 2 degrees Celsius, and the outdoor unit standing to the right

What you get

Four zones, one compressor

One 38,000 BTU outdoor unit runs all four indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing to leave alone.

Matching each unit to its room

A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.

Inverter compressor

The compressor varies its speed instead of cycling on and off. Published ratings are 20 SEER2 for cooling and 9.5 HSPF2 for heating on R32 refrigerant.

Built for a Canadian winter

A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -20°C (-4°F) and cooling up to 53°C (127°F).

Line sets and wiring supplied

Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire, plus a 8 ft drain hose. That is the material most quotes list separately, four times over on a system this size.

Electrical supply

The outdoor unit runs on 208-230V 60Hz. This is not a standard 15 amp household outlet. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.

Controls

Wifi app, a remote with a digital display for each zone, and voice control through Alexa or Google Home. A 24 hour timer and a child lock are built in.

Filters you can rinse

The indoor filters pull out, rinse under a tap and go back in. Four heads means four sets, and clean filters are the cheapest way to keep airflow and running cost where they should be.

Specifications

Blast Pro, 38,000 BTU outdoor unit with 9,000, 12,000, 12,000 and 12,000 BTU indoor units
Zones 4 (one outdoor unit, four indoor units)
Outdoor unit capacity 38,000 BTU
Indoor unit capacities 9,000, 12,000, 12,000 and 12,000 BTU
System type Ductless heat pump, cooling and heating
SEER2 (cooling) 20
HSPF2 (heating) 9.5
Refrigerant R32
Power supply 208-230V 60Hz
Heating range Down to -20°C (-4°F)
Cooling range Up to 53°C (127°F)
Operating modes 7: auto, cool, heat, dry, fan, ECO, sleep
Fan speeds 8: auto, mute, low, low-mid, mid, mid-high, high, turbo
Indoor sound level From 28 dB
Line set supplied 16 ft per zone, insulated copper (gas and liquid)
Communication wire 19 ft per zone
Drain hose 8 ft per zone
Outdoor unit size 42.64 x 19.45 x 33.78 in (L x W x H)
Indoor unit size, 9,000 BTU 31.93 x 7.48 x 12.05 in (L x W x H)
Indoor unit size, 12,000 BTU 31.93 x 7.48 x 12.05 in (L x W x H)
Colour White
Manufacturer SKU 26783816_Blastpro-38K-23

Capacity by zone

Rated capacity of each of the four zones in BTU Zone 19,000 BTUZone 212,000 BTUZone 312,000 BTUZone 412,000 BTUOutdoor unit rated 38,000 BTU
Rated capacity of each indoor unit in this configuration, drawn to the same scale, with the outdoor unit total underneath. At the common rule of thumb of 20 to 25 BTU per square foot, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Use CSA F280-12 for a real load calculation.

How it compares

Three ways people usually fix four uneven rooms in a Canadian home. This is how they differ in practice, not in price.

  This 4 zone system A window or portable unit per room Adding central ducted air
Separate temperature per room Yes, four independent set points Yes, but each room needs its own machine Usually one thermostat for the whole zone
Heats as well as cools Yes, rated to -20°C (-4°F) Many are cooling only Depends on the furnace or air handler fitted
Ductwork None, one cored hole per zone None Full duct network to every room
Machines outside One outdoor unit One in every window One condenser plus the indoor plant
Windows stay clear Yes No Yes
Who installs it Licensed HVAC and electrical trades You do, out of the carton Licensed trades, often several days on site

Shipping

Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.

Returns

Return within 14 days of purchase, unused, in original condition and packaging.

Warranty

Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.

Who is this perfect for?

A nursery, office or den beside three main rooms

The 9,000 BTU zone suits a small room of roughly 360 to 450 sq ft. The three 12,000 BTU zones cover the larger rooms at roughly 480 to 600 sq ft each.

Homes with no ducts to extend

Older houses, additions, attic conversions and finished basements rarely have duct where it is needed. Four zones from one outdoor unit avoids opening up ceilings.

Households that want heat as well as cooling

This is a heat pump, not a cooling only air conditioner. It carries a 9.5 HSPF2 heating rating and a chassis electrical heater on the outdoor unit for cold weather.

Dimension chart listing indoor unit sizes from 9,000 to 24,000 BTU and outdoor unit sizes from 20,000 to 38,000 BTU, beside a wall mounted indoor unit and an outdoor unit

What we stand behind

  • Ships from a Canadian warehouse, with free shipping on orders over $150
  • 14 day returns on unused items in original condition and packaging
  • Covered by the manufacturer's own warranty for material and manufacturing defects
  • Line sets, communication wire and a controller for every one of the four zones are in the box

Frequently asked questions

How much space will each indoor unit cover?

Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Poor insulation, large west facing windows or a 9 ft ceiling all push the figure up.

The four indoor units add up to 45,000 BTU but the outdoor unit is 38,000 BTU. Is that a mistake?

No. On any multi zone system the indoor ratings are not meant to be added together, and multi zone sizing guides say so plainly. The 38,000 BTU figure is what the outdoor unit can deliver at one time, shared among whichever zones are calling for it. Four rooms rarely peak at the same moment, which is why this combination is offered.

How cold can it get outside before it stops heating?

The manufacturer rates low ambient heating down to -20°C (-4°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most newer units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.

Can I install this myself in Canada, and does it run on a normal outlet?

No on both counts. The outdoor unit runs on 208-230V 60Hz, so it needs its own branch circuit and an electrician, not a wall socket. Refrigerant work is also regulated: Ontario, for example, states that only a certified technician may remove, discharge, handle and dispose of refrigerants including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of that. Other provinces have their own halocarbon rules, and the federal Code of Practice says the same thing in plainer terms.