36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 2
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 3
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 4
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 5
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 6
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 7
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 8
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 9
-40%
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 2
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 3
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 4
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 5
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 6
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 7
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 8
36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K view 9

UltrEco 36,000 BTU 3 Zone Mini Split Heat Pump, 23 SEER2, Wifi, 9K + 9K + 24K

sold in last days
Regular price $6,815.00 Sale price $4,089.00
Save $2,726.00
Only 3 available

Fast delivery

Arrives quickly and safely

Buyer protection

Covered end to end

Secure packaging

Damage-free guarantee

Ships from

ValuHub Fulfillment

36000 BTU 3 Zone 23 SEER2 Mini Split Air Conditioner Wifi Enabled with Heat Pump-9K + 9K + 24K

UltrEco 36,000 BTU 3 Zone Mini Split Heat Pump, 23 SEER2, Wifi, 9K + 9K + 24K

$4,089.00
Description

UltrEco 36,000 BTU 3 Zone Mini Split Heat Pump, 23 SEER2, Wifi, 9K + 9K + 24K

One 36,000 BTU outdoor unit feeds three indoor units of 9,000, 9,000 and 24,000 BTU, each with its own set point. It runs on R32 refrigerant, is rated 23 SEER2 and 10 HSPF2, and the manufacturer lists heating down to -25°C (-13°F).

23 SEER2 coolingHeating rated to -25°CR32 refrigerantWifi app and remote per zone

The one room that never matches the rest of the house

What usually goes wrong

A bedroom over the garage bakes in July while the basement stays cold. A window unit fixes one room and takes the window with it. Running the whole house harder to fix one room costs money and still misses the far corner.

How this configuration answers it

Three indoor units of 9,000, 9,000 and 24,000 BTU each get their own controller and their own temperature. Run the 24,000 BTU unit hard in the problem room and leave the other two off. Only the zones you switch on draw from the 36,000 BTU outdoor unit.

This is a heat pump, so the same equipment that cools in July reverses and heats in January. One outdoor unit, three indoor units, three independent set points.

Three stacked white indoor units in front of an outdoor condenser, with coiled copper line sets, three remotes and a phone app screen

Three rooms' worth of equipment in one photo

Stacked at the front are the three indoor units, rated 9,000, 9,000 and 24,000 BTU. Behind them sits the 36,000 BTU outdoor unit, and off to the side is the insulated copper, wiring, tape and putty for all three runs. Three remotes and the phone app share the controls.

Filters that rinse instead of being replaced

No cartridge to reorder. The panel lifts, the mesh filters come out, and they wash under a tap. A blocked filter makes the unit work harder for less air, so this is the five minute job worth putting in the calendar.

Open indoor unit showing the removable mesh filters, with an inset photo of a filter held under a running tap
Flat lay of the package contents showing the outdoor unit, indoor units, copper pipes, communication wire, drain hose, remotes and fixings with quantities labelled

Counting what is in the carton

One outdoor unit, three indoor units, and three of everything that links them: a 16 ft copper line set (gas and liquid), 13 ft of communication wire and a 6.5 ft drain hose per zone, plus wall sleeves, caps, screw kits, putty and tape. A remote and holder comes with each indoor unit.

January on the north side of the house

Frozen meltwater in the base pan is what kills an outdoor unit in a Canadian winter. A chassis heating element in this one keeps that pan clear. Rated limits are -25°C (-13°F) for heating and 52°C (125°F) for cooling, and output falls as it gets colder, so keep a second heat source for deep cold.

Snow-covered outdoor unit with the heating element glowing along the base and the low and high ambient ratings shown on either side

What you get

Three zones, one compressor

One 36,000 BTU outdoor unit runs all three indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing.

Matching each unit to its room

A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 24,000 BTU unit suits roughly 960 to 1,200 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.

Inverter compressor

The compressor varies its speed instead of cycling on and off. Published ratings are 23 SEER2 for cooling and 10 HSPF2 for heating.

Built for a Canadian winter

A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 52°C (125°F).

Line sets and wiring supplied

Each zone gets a 16 ft insulated copper line set and 13 ft of communication wire, plus a 6.5 ft drain hose. That is the material most quotes list separately.

Electrical supply

The outdoor unit runs on 208-230V~60Hz, single phase. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.

Controls

Wifi app plus a remote with a digital display for each zone, and a 24 hour timer.

Filters you can rinse

The indoor filters pull out, rinse under a tap and go back in. Clean filters are the cheapest way to keep airflow and running cost where they should be.

Specifications

UltrEco, 36,000 BTU outdoor unit with 9,000, 9,000 and 24,000 BTU indoor units
Zones 3 (one outdoor unit, three indoor units)
Outdoor unit capacity 36,000 BTU
Indoor unit capacities 9,000, 9,000 and 24,000 BTU
System type Ductless heat pump, cooling and heating
SEER2 (cooling) 23
HSPF2 (heating) 10
Refrigerant R32
Power supply 208-230V~60Hz, single phase
Heating range Down to -25°C (-13°F)
Cooling range Up to 52°C (125°F)
Operating modes 6: auto, cool, heat, dry, fan, sleep
Fan speeds 5: auto, low, mid, high, strong
Indoor sound level From 30 dB
Certification ENERGY STAR, ETL and AHRI
Line set supplied 16 ft per zone, insulated copper (gas and liquid)
Communication wire 13 ft per zone
Drain hose 6.5 ft per zone
Outdoor unit size 41.2 x 17.9 x 31.8 in (L x W x H)
Indoor unit size, 9,000 BTU 31 x 7.8 x 11.5 in (L x W x H)
Indoor unit size, 24,000 BTU 44.1 x 9.1 x 13 in (L x W x H)
Colour White
Manufacturer SKU 165734298_UltrEco-36K-33

Capacity by zone

Rated capacity of each zone in BTU Zone 19,000 BTUZone 29,000 BTUZone 324,000 BTUOutdoor unit rated 36,000 BTU
Rated capacity of each indoor unit in this configuration, drawn to the same scale, with the outdoor unit total underneath. At the common rule of thumb of 20 to 25 BTU per square foot: Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 24,000 BTU unit suits roughly 960 to 1,200 sq ft. Use CSA F280-12 for a real load calculation.

How it compares

Three ways people usually fix uneven rooms in a Canadian home. This is how they differ in practice, not in price.

  This 3 zone system A window or portable unit per room Adding central ducted air
Separate temperature per room Yes, three independent set points Yes, but each room needs its own machine Usually one thermostat for the whole zone
Heats as well as cools Yes, rated to -25°C (-13°F) Many are cooling only Depends on the furnace or air handler fitted
Ductwork None, one cored hole per zone None Full duct network to every room
Indoor equipment on show Three slim units mounted high on a wall A machine in every window Vents and returns
Windows stay clear Yes No Yes
Who installs it Licensed HVAC and electrical trades You do, out of the carton Licensed trades, often several days on site

Shipping

Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.

Returns

Return within 14 days of purchase, unused, in original condition and packaging.

Warranty

Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.

Who is this perfect for?

A big room plus two ordinary ones

The 24,000 BTU unit is sized for an open living and dining space, roughly 960 to 1,200 sq ft. The other two zones cover normal bedrooms without oversizing them.

Homes with no ducts to extend

Older houses, additions, attic conversions and finished basements rarely have ducts where they are needed. Three zones from one outdoor unit avoids opening up ceilings.

People who want heat as well as cooling

This is a heat pump, not a cooling-only air conditioner. It carries an HSPF2 heating rating of 10 and a chassis heater for winter operation.

Dimension chart showing the size of every indoor unit and outdoor unit in the range, with drawings of both units

What we stand behind

  • Ships from a Canadian warehouse, with free shipping on orders over $150
  • 14 day returns on unused items in original condition and packaging
  • Covered by the manufacturer's own warranty for material and manufacturing defects
  • Line sets, communication wire and a controller for every zone are in the box

Frequently asked questions

How much space will each indoor unit cover?

Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 24,000 BTU unit suits roughly 960 to 1,200 sq ft. Poor insulation, big west-facing windows or a 9 ft ceiling all push that figure up.

The three indoor units add up to 42,000 BTU but the outdoor unit is 36,000 BTU. Is that a mistake?

No. On any multi-zone system the indoor ratings are not meant to be added together, and sizing guides for multi-zone equipment say so plainly. The 36,000 BTU figure is what the outdoor unit can deliver at one time, and it is shared among whichever zones are calling for it. Three rooms rarely peak at the same moment, which is why this combination is offered.

How cold can it get outside before it stops heating?

The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.

Can I install this myself in Canada?

Plan on a licensed installer. In Ontario, for example, the province states that by law only a certified technician may remove, discharge, handle and dispose of refrigerants, including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of the refrigerant certificate. Other provinces have their own halocarbon rules. The federal Code of Practice says the same thing in plainer terms: the technician doing work that could release refrigerant must hold the proper environmental certification. The 208-230V~60Hz, single phase power supply also means an electrician and a dedicated circuit.

Recently viewed products