X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 2
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 3
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 4
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 5
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 6
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 7
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 8
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 9
-25%
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 2
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 3
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 4
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 5
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 6
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 7
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 8
X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K view 9

X-Pro 35,000 BTU 4 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K + 12K

sold in last days
Regular price $8,723.00 Sale price $6,499.00
Save $2,224.00
In Stock

Fast delivery

Arrives quickly and safely

Buyer protection

Covered end to end

Secure packaging

Damage-free guarantee

Ships from

ValuHub Fulfillment

X-Pro 35000 BTU 4 Zone 22.5 SEER2 Concealed Ducted Mini Split AC-9K + 9K + 9K + 12K

X-Pro 35,000 BTU 4 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K + 12K

$6,499.00
Description

X-Pro 35,000 BTU 4 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K + 12K

Three 9,000 BTU ducted air handlers and one 12,000 BTU unit share one 35,000 BTU condenser, so the busiest room gets the extra capacity without oversizing the other three. Published ratings are 22.5 SEER2 on cooling and 10 HSPF2 on heating, running R454B refrigerant, with heating listed down to -25°C (-13°F).

22.5 SEER2 coolingHeating rated to -25°CR454B refrigerantWall thermostat, app and voice

One room in the house always runs a couple of degrees out

What usually goes wrong

Three rooms behave and the fourth never quite matches. It might face west, sit over the garage, or have one more window than the others. Turning the whole system harder is an expensive way to fix one room.

How this configuration answers it

The odd room gets a 12,000 BTU head instead of the 9,000 BTU used on the other three, with its own wall thermostat to hold it there. Only the zones that are switched on draw from the 35,000 BTU outdoor unit.

Four ducted zones off one condenser sits between wall mounted heads and a full central system. The air handlers hide above a ceiling, so each room shows only a grille. Everything indoors connects back to the same 35,000 BTU outdoor unit through its own insulated copper line set.

Four beige concealed ducted air handlers stacked above a white outdoor unit, with a coiled copper line set, four wall thermostats, four remotes and a phone showing the app

Everything that arrives on the pallet

The beige boxes are the air handlers, and they are meant to be hidden above a ceiling or in a bulkhead. Four of them, rated 9,000, 9,000, 9,000 and 12,000 BTU, run from one 35,000 BTU outdoor unit. Each zone ships with a wall thermostat as well as a remote, which is the control most people end up using on a ducted system.

What the yellow label says

The label reads 22.5 SEER2 for cooling and 10 HSPF2 for heating, on R454B refrigerant. The graph beside it is the inverter argument in one picture: a flat line holding the set point against a line that overshoots and undershoots all day. Ducted air handlers gain from that, because a ceiling grille gives you less warning when a room drifts.

EnergyGuide label and an inverter technology graph above a ceiling grille, with R454B refrigerant, 22.5 SEER2 and 10 HSPF2 shown as blue blocks below
White outdoor unit standing in deep snow outside a glass walled living room, with the chassis heater glowing at its base, captioned 55 degrees Celsius high ambient cooling and minus 25 degrees Celsius low ambient heating

Built for a Canadian winter

Chassis electrical heating keeps the base pan clear so meltwater can drain instead of freezing solid. The published window is heating down to -25°C (-13°F) and cooling up to 55°C (131°F). Natural Resources Canada notes heat pumps deliver less as the air gets colder, so keep a backup heat source for the deepest cold.

Where a hidden air handler earns its keep

The four photos are the usual homes for this format: a living room with a wall of glass, a bedroom where a wall unit would sit over the bed, an office, and a small commercial room. In each one the only visible part is a grille. The air handler itself sits above the ceiling with the drain and the line set.

A beige ducted air handler above four photos labelled living room, bedroom, office and restaurant, each showing a slim ceiling grille and airflow

What you get

Four zones, one compressor

One 35,000 BTU outdoor unit runs all four ducted air handlers. Each zone starts, stops and holds its own temperature, so an empty room costs nothing to leave alone.

Matching each unit to its room

A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.

Inverter compressor

The compressor varies its speed instead of cycling on and off. Published ratings are 22.5 SEER2 for cooling and 10 HSPF2 for heating on R454B refrigerant.

Built for a Canadian winter

A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F).

Line sets and wiring supplied

Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire, plus a drain hose. That is the material most quotes list separately, four times over on a system this size.

Electrical supply

The outdoor unit runs on 208-230V 60Hz. This is not a standard 15 amp household outlet. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.

A thermostat for every zone

Four wired wall thermostats, four remotes, the phone app and voice control through Alexa or Google Home. A 24 hour timer and a child lock are built in.

Self clean and a washable filter

A self clean cycle dries the coil after cooling, and the filter washes out. Both matter more on a hidden air handler, because nobody walks past it and notices.

Specifications

X-Pro, 35,000 BTU outdoor unit with 9,000, 9,000, 9,000 and 12,000 BTU air handlers
Zones 4 (one outdoor unit, four ducted air handlers)
Outdoor unit capacity 35,000 BTU
Air handler capacities 9,000, 9,000, 9,000 and 12,000 BTU
System type Concealed ducted heat pump, cooling and heating
SEER2 (cooling) 22.5
HSPF2 (heating) 10
Refrigerant R454B
Power supply 208-230V 60Hz
Heating range Down to -25°C (-13°F)
Cooling range Up to 55°C (131°F)
Operating modes 7: auto, cool, heat, dry, fan, ECO, sleep
Fan speeds 8: auto, mute, low, low-mid, mid, mid-high, high, turbo
Indoor sound level From 28 dB
Certification ETL and AHRI
Line set supplied 16 ft per zone, insulated copper (gas and liquid)
Communication wire 19 ft per zone
Drain hose One per zone, length not published
Outdoor unit size 42.28 x 18.43 x 33.58 in (L x W x H)
Colour White outdoor unit, beige ducted air handlers
Manufacturer SKU 59356934_X-Pro-DC-35K-19

Capacity by zone

Rated capacity of each of the four zones in BTU Zone 19,000 BTUZone 29,000 BTUZone 39,000 BTUZone 412,000 BTUOutdoor unit rated 35,000 BTU
Rated capacity of each indoor unit in this configuration, drawn to the same scale, with the outdoor unit total underneath. At the common rule of thumb of 20 to 25 BTU per square foot, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Use CSA F280-12 for a real load calculation.

How it compares

Three ways to condition four rooms in a Canadian home that has no usable ductwork. This is how they differ in practice, not in price.

  This 4 zone ducted system Four wall mounted heads A central furnace and air handler
Separate temperature per room Yes, four independent set points Yes, four independent set points Usually one thermostat for the whole zone
Visible indoor equipment A slim ceiling grille in each room A box high on the wall in each room Supply and return vents
Ductwork needed A short run per zone, hidden above the ceiling None Full duct network to every room
Ceiling or bulkhead space Required above each air handler Not required Required for the trunk and branches
Heats as well as cools Yes, rated to -25°C (-13°F) Yes on a heat pump model Depends on the furnace or air handler fitted
Who installs it Licensed HVAC and electrical trades Licensed HVAC and electrical trades Licensed trades, often several days on site

Shipping

Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.

Returns

Return within 14 days of purchase, unused, in original condition and packaging.

Warranty

Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.

Who is this perfect for?

Three bedrooms and a slightly larger main room

The 12,000 BTU zone suits roughly 480 to 600 sq ft and the three 9,000 BTU zones roughly 360 to 450 sq ft each. A common shape for a bungalow or a semi.

Rooms with nowhere to put a wall unit

Glass walls, a cornice worth keeping, a bed under the only free wall. A concealed air handler above the ceiling leaves a slim grille and nothing else on show.

Households that want heat as well as cooling

This is a heat pump, not a cooling only air conditioner. It carries a 10 HSPF2 heating rating and a chassis electrical heater on the outdoor unit for cold weather.

Dimension chart listing ducted air handler sizes from 9,000 to 24,000 BTU and outdoor unit sizes from 18,000 to 35,000 BTU, with ETL and AHRI certified marks in the corner

What we stand behind

  • Ships from a Canadian warehouse, with free shipping on orders over $150
  • 14 day returns on unused items in original condition and packaging
  • Covered by the manufacturer's own warranty for material and manufacturing defects
  • Line sets, communication wire and a controller for every one of the four zones are in the box

Frequently asked questions

How much space will each ducted air handler cover?

Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. On that basis a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Poor insulation, large west facing windows or a 9 ft ceiling all push the figure up.

The four ducted air handlers add up to 39,000 BTU but the outdoor unit is 35,000 BTU. Is that a mistake?

No. On any multi zone system the indoor ratings are not meant to be added together, and multi zone sizing guides say so plainly. The 35,000 BTU figure is what the outdoor unit can deliver at one time, shared among whichever zones are calling for it. Four rooms rarely peak at the same moment, which is why this combination is offered.

How cold can it get outside before it stops heating?

The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most newer units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.

Can I install this myself in Canada, and does it run on a normal outlet?

No on both counts. The outdoor unit runs on 208-230V 60Hz, so it needs its own branch circuit and an electrician, not a wall socket. Refrigerant work is also regulated: Ontario, for example, states that only a certified technician may remove, discharge, handle and dispose of refrigerants including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of that. Other provinces have their own halocarbon rules, and the federal Code of Practice says the same thing in plainer terms.