X-Pro 35,000 BTU 3 Zone Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 12K + 18K
Fast delivery
Arrives quickly and safely
Buyer protection
Covered end to end
Secure packaging
Damage-free guarantee
Ships from
ValuHub Fulfillment
X-Pro 35,000 BTU 3 Zone Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 12K + 18K
Description
X-Pro 35,000 BTU 3 Zone Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 12K + 18K
Split across three zones at 9,000, 12,000 and 18,000 BTU, this 35,000 BTU heat pump cools in summer and heats in winter. The manufacturer rates it 22.5 SEER2 for cooling and 10 HSPF2 for heating, with R454B refrigerant and low ambient heating to -25°C (-13°F).
Rooms that never had ducts in the first place
What usually goes wrong
Attic conversions, finished basements, additions and garages often have no ductwork at all. Extending ducts means opening ceilings and walls. Portable units need a hose out a window and have to be stored every autumn.
How this configuration answers it
Each zone needs one cored hole for the copper line set, communication wire and drain, not a duct run. This kit ships with a 16 ft line set, 19 ft of wire and a controller per zone, sized at 9,000, 12,000 and 18,000 BTU.
One outdoor unit, three rooms, three numbers on three controllers. The compressor speeds up or eases off to suit whichever zones are calling, instead of running flat out.

Three rooms' worth of equipment in one photo
Stacked at the front are the three indoor units, rated 9,000, 12,000 and 18,000 BTU. Behind them sits the 35,000 BTU outdoor unit, and off to the side is the insulated copper, wiring, tape and putty for all three runs. Three remotes and the phone app share the controls.
What happens when it gets properly cold
The outdoor unit carries a chassis electrical heater, which keeps the base pan clear so meltwater does not freeze under the coil. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F). Natural Resources Canada notes most air source heat pumps stop somewhere between -15°C and -25°C, so plan on a backup heat source for the coldest nights.


Reading the yellow label
The EnergyGuide panel in this photo is the honest summary: 22.5 SEER2 on cooling, 10 HSPF2 on heating, with R454B refrigerant in the system. The graph beside it shows why an inverter holds temperature better than a fixed-speed compressor that only knows on and off. It carries ENERGY STAR, ETL and AHRI certification.
Why the louvres move in four directions
Air thrown in one fixed direction leaves cold corners in summer and a warm ceiling in winter. The 4D swing sweeps up and down and side to side, which is what makes a single wall unit work in a room that is not square. The 18,000 BTU zone benefits most from the wider throw.

What you get
Three zones, one compressor
One 35,000 BTU outdoor unit runs all three indoor units. Each zone starts, stops and holds its own temperature, so an empty room costs nothing.
Matching each unit to its room
A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft, a 12,000 BTU unit suits roughly 480 to 600 sq ft and an 18,000 BTU unit suits roughly 720 to 900 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.
Inverter compressor
The compressor varies its speed instead of cycling on and off. Published ratings are 22.5 SEER2 for cooling and 10 HSPF2 for heating.
Built for a Canadian winter
A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F).
Line sets and wiring supplied
Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire. That is the material most quotes list separately.
Electrical supply
The outdoor unit runs on 208-230V 60Hz. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.
Controls
Wifi app, a remote with a digital display for each zone, Amazon Alexa and Google Home.
Filters you can rinse
The indoor filters pull out, rinse under a tap and go back in. Clean filters are the cheapest way to keep airflow and running cost where they should be.
Specifications
| Zones | 3 (one outdoor unit, three indoor units) |
|---|---|
| Outdoor unit capacity | 35,000 BTU |
| Indoor unit capacities | 9,000, 12,000 and 18,000 BTU |
| System type | Ductless heat pump, cooling and heating |
| SEER2 (cooling) | 22.5 |
| HSPF2 (heating) | 10 |
| Refrigerant | R454B |
| Power supply | 208-230V 60Hz |
| Heating range | Down to -25°C (-13°F) |
| Cooling range | Up to 55°C (131°F) |
| Operating modes | 7: auto, cool, heat, dry, fan, ECO, sleep |
| Fan speeds | 8: auto, mute, low, low-mid, mid, mid-high, high, turbo |
| Indoor sound level | From 30 dB |
| Certification | ENERGY STAR, ETL and AHRI |
| Line set supplied | 16 ft per zone, insulated copper (gas and liquid) |
| Communication wire | 19 ft per zone |
| Outdoor unit size | 42.28 x 18.43 x 33.58 in (L x W x H) |
| Indoor unit size, 9,000 BTU | 32.28 x 7.68 x 12.05 in (L x W x H) |
| Indoor unit size, 12,000 BTU | 36.22 x 7.68 x 12.05 in (L x W x H) |
| Indoor unit size, 18,000 BTU | 43.19 x 8.74 x 13.07 in (L x W x H) |
| Colour | White |
| Manufacturer SKU | 78443122_X-Pro-36K-13 |
Capacity by zone
How it compares
Three ways people usually fix uneven rooms in a Canadian home. This is how they differ in practice, not in price.
| This 3 zone system | A window or portable unit per room | Adding central ducted air | |
|---|---|---|---|
| Separate temperature per room | Yes, three independent set points | Yes, but each room needs its own machine | Usually one thermostat for the whole zone |
| Heats as well as cools | Yes, rated to -25°C (-13°F) | Many are cooling only | Depends on the furnace or air handler fitted |
| Ductwork | None, one cored hole per zone | None | Full duct network to every room |
| Indoor equipment on show | Three slim units mounted high on a wall | A machine in every window | Vents and returns |
| Windows stay clear | Yes | No | Yes |
| Who installs it | Licensed HVAC and electrical trades | You do, out of the carton | Licensed trades, often several days on site |
Shipping
Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.
Returns
Return within 14 days of purchase, unused, in original condition and packaging.
Warranty
Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.
Who is this perfect for?
A big room plus two ordinary ones
The 18,000 BTU unit is sized for an open living and dining space, roughly 720 to 900 sq ft. The other two zones cover normal bedrooms without oversizing them.
Homes with no ducts to extend
Older houses, additions, attic conversions and finished basements rarely have ducts where they are needed. Three zones from one outdoor unit avoids opening up ceilings.
People who want heat as well as cooling
This is a heat pump, not a cooling-only air conditioner. It carries an HSPF2 heating rating of 10 and a chassis heater for winter operation.

What we stand behind
- Ships from a Canadian warehouse, with free shipping on orders over $150
- 14 day returns on unused items in original condition and packaging
- Covered by the manufacturer's own warranty for material and manufacturing defects
- Line sets, communication wire and a controller for every zone are in the box
Frequently asked questions
How much space will each indoor unit cover?
Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft, a 12,000 BTU unit suits roughly 480 to 600 sq ft and an 18,000 BTU unit suits roughly 720 to 900 sq ft. Poor insulation, big west-facing windows or a 9 ft ceiling all push that figure up.
The three indoor units add up to 39,000 BTU but the outdoor unit is 35,000 BTU. Is that a mistake?
No. On any multi-zone system the indoor ratings are not meant to be added together, and sizing guides for multi-zone equipment say so plainly. The 35,000 BTU figure is what the outdoor unit can deliver at one time, and it is shared among whichever zones are calling for it. Three rooms rarely peak at the same moment, which is why this combination is offered.
How cold can it get outside before it stops heating?
The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.
Can I install this myself in Canada?
Plan on a licensed installer. In Ontario, for example, the province states that by law only a certified technician may remove, discharge, handle and dispose of refrigerants, including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of the refrigerant certificate. Other provinces have their own halocarbon rules. The federal Code of Practice says the same thing in plainer terms: the technician doing work that could release refrigerant must hold the proper environmental certification. The 208-230V 60Hz power supply also means an electrician and a dedicated circuit.




















