X-Pro 35,000 BTU 3 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K
Fast delivery
Arrives quickly and safely
Buyer protection
Covered end to end
Secure packaging
Damage-free guarantee
Ships from
ValuHub Fulfillment
X-Pro 35,000 BTU 3 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K
Description
X-Pro 35,000 BTU 3 Zone Ducted Mini Split Heat Pump, 22.5 SEER2, Wifi, 9K + 9K + 9K
Every zone gets its own indoor unit here: 9,000 BTU, 9,000 BTU and 9,000 BTU, running on R454B refrigerant from a shared 35,000 BTU condenser. Cooling is rated 22.5 SEER2 and heating 10 HSPF2, on R454B refrigerant, with a chassis heater that keeps the outdoor unit working to -25°C (-13°F).
Three condensers along the side of the house
What usually goes wrong
Treating three rooms one at a time means three separate systems, three outdoor units and three sets of line covers on the wall. On a narrow lot or a townhouse there is simply nowhere to put them.
How this configuration answers it
One 35,000 BTU outdoor unit runs all three zones here, at 9,000, 9,000 and 9,000 BTU. The refrigerant lines run to concealed air handlers rather than to three separate condensers, so the outside of the building stays as it was.
This is a heat pump, so the same equipment that cools in July reverses and heats in January. One outdoor unit, three indoor units, three independent set points.

Everything the installer unpacks
The photo shows the full kit: three slim ducted air handlers rated 9,000, 9,000 and 9,000 BTU, the 35,000 BTU outdoor unit, coiled insulated copper and the wall thermostats. The air handlers hide above a ceiling or in a bulkhead, so the only thing on show in the room is a supply grille and a return.
Reading the yellow label
The EnergyGuide panel in this photo is the honest summary: 22.5 SEER2 on cooling, 10 HSPF2 on heating, with R454B refrigerant in the system. The graph beside it shows why an inverter holds temperature better than a fixed-speed compressor that only knows on and off. It carries ETL and AHRI certification.


Heating and cooling through the same grilles
Nothing changes in the room between seasons: the same ducted handler and the same grilles carry cool air in summer and warm air in winter. Seven modes, eight fan speeds, a 24 hour timer, a child lock and a self-clean function are all on the control.
Four ways to change the temperature
Each zone comes with a wall thermostat, which is the sensible choice for a ducted air handler you cannot point a remote at. A handheld remote, the phone app, Amazon Alexa and Google Home all work as well, and a child lock keeps settings where you left them.

What you get
Three zones, one compressor
One 35,000 BTU outdoor unit runs all three ducted air handlers. Each zone starts, stops and holds its own temperature, so an empty room costs nothing.
Matching each unit to its room
A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). Each 9,000 BTU unit suits roughly 360 to 450 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.
Inverter compressor
The compressor varies its speed instead of cycling on and off. Published ratings are 22.5 SEER2 for cooling and 10 HSPF2 for heating.
Built for a Canadian winter
A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F).
Line sets and wiring supplied
Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire. That is the material most quotes list separately.
Electrical supply
The outdoor unit runs on 208-230V 60Hz. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.
Controls
A wall thermostat for each zone, plus a handheld remote, the phone app, Amazon Alexa and Google Home.
Nothing on the wall
The air handlers sit above a ceiling or inside a bulkhead and feed short duct runs to grilles. Only the supply and return grilles are visible in the room.
Specifications
| Zones | 3 (one outdoor unit, three ducted air handlers) |
|---|---|
| Outdoor unit capacity | 35,000 BTU |
| Air handler capacities | 9,000, 9,000 and 9,000 BTU |
| System type | Concealed ducted heat pump, cooling and heating |
| SEER2 (cooling) | 22.5 |
| HSPF2 (heating) | 10 |
| Refrigerant | R454B |
| Power supply | 208-230V 60Hz |
| Heating range | Down to -25°C (-13°F) |
| Cooling range | Up to 55°C (131°F) |
| Operating modes | 7: auto, cool, heat, dry, fan, ECO, sleep |
| Fan speeds | 8: auto, mute, low, low-mid, mid, mid-high, high, turbo |
| Indoor sound level | From 28 dB |
| Certification | ETL and AHRI |
| Line set supplied | 16 ft per zone, insulated copper (gas and liquid) |
| Communication wire | 19 ft per zone |
| Outdoor unit size | 42.28 x 18.43 x 33.58 in (L x W x H) |
| Colour | White outdoor unit, beige ducted air handlers |
| Manufacturer SKU | 25437573_X-Pro-DC-35K-8 |
Capacity by zone
How it compares
Three ways people usually fix uneven rooms in a Canadian home. This is how they differ in practice, not in price.
| This 3 zone system | A window or portable unit per room | Adding central ducted air | |
|---|---|---|---|
| Separate temperature per room | Yes, three independent set points | Yes, but each room needs its own machine | Usually one thermostat for the whole zone |
| Heats as well as cools | Yes, rated to -25°C (-13°F) | Many are cooling only | Depends on the furnace or air handler fitted |
| Ductwork | Short runs from each concealed air handler to its grilles | None | Full duct network to every room |
| Indoor equipment on show | Supply and return grilles only | A machine in every window | Vents and returns |
| Windows stay clear | Yes | No | Yes |
| Who installs it | Licensed HVAC and electrical trades | You do, out of the carton | Licensed trades, often several days on site |
Shipping
Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.
Returns
Return within 14 days of purchase, unused, in original condition and packaging.
Warranty
Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.
Who is this perfect for?
Three rooms of similar size
All three units are 9,000 BTU, so this suits three comparable spaces of roughly 360 to 450 sq ft each: bedrooms, a home office, a finished basement room.
Rooms that should not show the equipment
Tall-window living rooms, heritage interiors, offices and dining rooms all look better without a unit on the wall. The handler hides in a ceiling void and only the grilles are visible.
People who want heat as well as cooling
This is a heat pump, not a cooling-only air conditioner. It carries an HSPF2 heating rating of 10 and a chassis heater for winter operation.

What we stand behind
- Ships from a Canadian warehouse, with free shipping on orders over $150
- 14 day returns on unused items in original condition and packaging
- Covered by the manufacturer's own warranty for material and manufacturing defects
- Line sets, communication wire and a controller for every zone are in the box
Frequently asked questions
How much space will each indoor unit cover?
Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. Each 9,000 BTU unit suits roughly 360 to 450 sq ft. Poor insulation, big west-facing windows or a 9 ft ceiling all push that figure up.
The three indoor units add up to 27,000 BTU and the outdoor unit is rated 35,000 BTU. Why the gap?
Multi-zone outdoor units come in fixed sizes and the indoor combinations are built around them, so the totals rarely land exactly. The spare capacity is not wasted: the inverter compressor simply runs at a lower speed, which is where a modulating system gets its efficiency. Either way, do not add the indoor ratings together to judge the system. The 35,000 BTU figure is what can be delivered at one time, shared among the zones that are calling.
How cold can it get outside before it stops heating?
The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.
Can I install this myself in Canada?
Plan on a licensed installer. In Ontario, for example, the province states that by law only a certified technician may remove, discharge, handle and dispose of refrigerants, including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of the refrigerant certificate. Other provinces have their own halocarbon rules. The federal Code of Practice says the same thing in plainer terms: the technician doing work that could release refrigerant must hold the proper environmental certification. The 208-230V 60Hz power supply also means an electrician and a dedicated circuit.




















