X-Pro 27,000 BTU 3 Zone Ducted Mini Split Heat Pump, 24 SEER2, Wifi, 9K + 12K + 12K
Fast delivery
Arrives quickly and safely
Buyer protection
Covered end to end
Secure packaging
Damage-free guarantee
Ships from
ValuHub Fulfillment
X-Pro 27,000 BTU 3 Zone Ducted Mini Split Heat Pump, 24 SEER2, Wifi, 9K + 12K + 12K
Description
X-Pro 27,000 BTU 3 Zone Ducted Mini Split Heat Pump, 24 SEER2, Wifi, 9K + 12K + 12K
The three ducted air handlers supplied measure 9,000, 12,000 and 12,000 BTU, and only the ones you switch on draw from the 27,000 BTU outdoor unit. It runs on R454B refrigerant, is rated 24 SEER2 and 10.5 HSPF2, and the manufacturer lists heating down to -25°C (-13°F).
The room where a box on the wall would look wrong
What usually goes wrong
Some rooms cannot take a wall unit. A front room with tall windows, a heritage ceiling, a bedroom with no spare wall, a small office suite. The usual answers are a portable unit with a hose out the window or nothing at all.
How this configuration answers it
Each of the three air handlers here (9,000, 12,000 and 12,000 BTU) sits above a ceiling or in a bulkhead and feeds short duct runs to grilles. Only the grilles show. A wall thermostat per zone does the controlling, and all three run from one 27,000 BTU outdoor unit.
Multi-zone means one compressor outside and three ducted air handlers hidden in the ceiling, each on its own controller. You heat or cool only the rooms you are actually using, and the rest of the house stays as it was.

The kit, before any of it disappears into a ceiling
Once it is installed you will never see most of this again. Three beige ducted air handlers at 9,000, 12,000 and 12,000 BTU, one 27,000 BTU outdoor unit, insulated copper for each zone and three wall thermostats, which are the only parts that stay in sight.
Where the 24 SEER2 number comes from
Inverter compressors ramp up and down instead of slamming on and off, which is what holds a room steady and keeps the meter from spiking. The EnergyGuide panel on this outdoor unit shows 24 SEER2 for cooling and 10.5 HSPF2 for heating, and the refrigerant is R454B. It carries ETL and AHRI certification.


One set of equipment for both seasons
The same air handler that cools in August reverses in November and pulls heat out of the outdoor air. Seven modes and eight fan speeds cover the range, and a self-clean cycle helps keep the coil and air path in better shape between services.
A thermostat on the wall, not a unit on it
Because the air handler is hidden, the control moves to a wall thermostat instead. One comes with each of the three zones. The app, the handheld remote, Amazon Alexa and Google Home are all there as alternatives, and the 24 hour timer runs the routine days.

What you get
Three zones, one compressor
One 27,000 BTU outdoor unit runs all three ducted air handlers. Each zone starts, stops and holds its own temperature, so an empty room costs nothing.
Matching each unit to its room
A common rule of thumb is 20 to 25 BTU per square foot (Carrier publishes 25). Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Natural Resources Canada points to CSA F280-12 for a proper load calculation.
Inverter compressor
The compressor varies its speed instead of cycling on and off. Published ratings are 24 SEER2 for cooling and 10.5 HSPF2 for heating.
Built for a Canadian winter
A chassis electrical heater keeps the outdoor base pan clear. The manufacturer rates heating down to -25°C (-13°F) and cooling up to 55°C (131°F).
Line sets and wiring supplied
Each zone gets a 16 ft insulated copper line set and 19 ft of communication wire. That is the material most quotes list separately.
Electrical supply
The outdoor unit runs on 208-230V 60Hz. It wants its own branch circuit, sized from the MCA and maximum breaker figures on the unit's own nameplate, with a disconnect within reach.
Controls
A wall thermostat for each zone, plus a handheld remote, the phone app, Amazon Alexa and Google Home.
Nothing on the wall
The air handlers sit above a ceiling or inside a bulkhead and feed short duct runs to grilles. Only the supply and return grilles are visible in the room.
Specifications
| Zones | 3 (one outdoor unit, three ducted air handlers) |
|---|---|
| Outdoor unit capacity | 27,000 BTU |
| Air handler capacities | 9,000, 12,000 and 12,000 BTU |
| System type | Concealed ducted heat pump, cooling and heating |
| SEER2 (cooling) | 24 |
| HSPF2 (heating) | 10.5 |
| Refrigerant | R454B |
| Power supply | 208-230V 60Hz |
| Heating range | Down to -25°C (-13°F) |
| Cooling range | Up to 55°C (131°F) |
| Operating modes | 7: auto, cool, heat, dry, fan, ECO, sleep |
| Fan speeds | 8: auto, mute, low, low-mid, mid, mid-high, high, turbo |
| Indoor sound level | From 28 dB |
| Certification | ETL and AHRI |
| Line set supplied | 16 ft per zone, insulated copper (gas and liquid) |
| Communication wire | 19 ft per zone |
| Outdoor unit size | 38.5 x 16.57 x 31.61 in (L x W x H) |
| Colour | White outdoor unit, beige ducted air handlers |
| Manufacturer SKU | 79375728_X-Pro-DC-27K-10 |
Capacity by zone
How it compares
Three ways people usually fix uneven rooms in a Canadian home. This is how they differ in practice, not in price.
| This 3 zone system | A window or portable unit per room | Adding central ducted air | |
|---|---|---|---|
| Separate temperature per room | Yes, three independent set points | Yes, but each room needs its own machine | Usually one thermostat for the whole zone |
| Heats as well as cools | Yes, rated to -25°C (-13°F) | Many are cooling only | Depends on the furnace or air handler fitted |
| Ductwork | Short runs from each concealed air handler to its grilles | None | Full duct network to every room |
| Indoor equipment on show | Supply and return grilles only | A machine in every window | Vents and returns |
| Windows stay clear | Yes | No | Yes |
| Who installs it | Licensed HVAC and electrical trades | You do, out of the carton | Licensed trades, often several days on site |
Shipping
Ships from a Canadian warehouse. Free shipping on orders over $150. Some remote areas, PO boxes and surcharge regions may be excluded or charged extra.
Returns
Return within 14 days of purchase, unused, in original condition and packaging.
Warranty
Covered directly by the manufacturer under their warranty terms for material and manufacturing defects.
Who is this perfect for?
A main room and two smaller ones
The 12,000 BTU unit takes the busiest space, roughly 480 to 600 sq ft, while the 9,000 BTU units handle quieter rooms. Capacity goes where the heat load actually is.
Rooms that should not show the equipment
Tall-window living rooms, heritage interiors, offices and dining rooms all look better without a unit on the wall. The handler hides in a ceiling void and only the grilles are visible.
People who want heat as well as cooling
This is a heat pump, not a cooling-only air conditioner. It carries an HSPF2 heating rating of 10.5 and a chassis heater for winter operation.

What we stand behind
- Ships from a Canadian warehouse, with free shipping on orders over $150
- 14 day returns on unused items in original condition and packaging
- Covered by the manufacturer's own warranty for material and manufacturing defects
- Line sets, communication wire and a controller for every zone are in the box
Frequently asked questions
How much space will each indoor unit cover?
Sizing runs off the heat load of the room, not just its floor area, and Natural Resources Canada points to CSA F280-12 for the real calculation. As a rough check, 20 to 25 BTU per square foot is the usual rule of thumb. Here, a 9,000 BTU unit suits roughly 360 to 450 sq ft and a 12,000 BTU unit suits roughly 480 to 600 sq ft. Poor insulation, big west-facing windows or a 9 ft ceiling all push that figure up.
The three indoor units add up to 33,000 BTU but the outdoor unit is 27,000 BTU. Is that a mistake?
No. On any multi-zone system the indoor ratings are not meant to be added together, and sizing guides for multi-zone equipment say so plainly. The 27,000 BTU figure is what the outdoor unit can deliver at one time, and it is shared among whichever zones are calling for it. Three rooms rarely peak at the same moment, which is why this combination is offered.
How cold can it get outside before it stops heating?
The manufacturer rates low ambient heating down to -25°C (-13°F), helped by an electric heater in the outdoor chassis. Natural Resources Canada notes that air source heat pumps lose capacity and efficiency as it gets colder, with typical COPs falling from 2.0 to 5.4 at 8°C to 1.1 to 3.7 at -8°C, and that most units have a minimum operating temperature between -15°C and -25°C. Keep a backup heat source for the coldest stretches.
Can I install this myself in Canada?
Plan on a licensed installer. In Ontario, for example, the province states that by law only a certified technician may remove, discharge, handle and dispose of refrigerants, including HFCs, and that mechanical work on refrigeration equipment needs a Certificate of Qualification on top of the refrigerant certificate. Other provinces have their own halocarbon rules. The federal Code of Practice says the same thing in plainer terms: the technician doing work that could release refrigerant must hold the proper environmental certification. The 208-230V 60Hz power supply also means an electrician and a dedicated circuit.